Alpha/Delta (Kinetic Operator) Installation and Maintenance Manual
Revision 1 - MAY 2023
123
CONNECTING HY5B VEHICLE DETECTORS
Table 8. Vehicle Detector - Configurable Functions
Display
Meaning
Installer Menu Setting Options
(Bold - Default)
OR 1
Outside Obstruction loop detector function
0= Pause closing only
1= Enable reverse to open
IR 1
Inside Obstruction loop detector function
0= Pause closing only
1= Enable reverse to open
DL 1
Vehicle detector logic
1 = Standard
(Close Timer does not begin
counting until all loops have cleared.)
2 = Quick close (Close Timer can count to
zero, even while loops are active, so the
gate will close as soon as the loops are
clear.)
3 = Forced time out (Close Timer is forced
to zero when both the OOLD & IOLD are
tripped simultaneously. Additionally, all
other close inputs are memorized and the
gate closes immediately when all open
commands and vehicle detector inputs are
clear.)
4 = Full Anti-tailgate (In addition to the
functions of 3, the gate stops during the
opening cycle when both OOLD & IOLD are
tripped simultaneously. When the OOLD
and IOLD loops are cleared, the gate closes
immediately.)
For additional information, refer to