wc_tx001396gb_FM10.fm
91
HI750
Burner Setup—Gas
Continued from the previous page.
Adjusting
pressure
Perform the procedure below to adjust the burner gas pressure at the regulator
(e)
.
1. Check that the vent
(g)
is clean and open.
2. Remove the cap
(f)
from the regulator.
3. Turn the screw
(e)
to adjust the burner gas pressure:
■
clockwise to increase pressure
■
counterclockwise to decrease pressure
Once the burner gas pressure is set:
4. Re-install the cap.
5. Shut down the machine.
6. Remove the manometer tube from the pressure test port.
7. Tighten the needle valve.
NOTICE:
Do not overtighten the needle valve. Damage to the needle valve will
occur.
Result
The burner gas pressure has now been checked and adjusted.
g
ghi_gr004914
wc_gr008501
e
wc_gr008502
f
e
Summary of Contents for HI750 Series
Page 6: ...ghi_tx001257gb_FM10 fm 6 Foreword HI750 ...
Page 27: ...HI750 Labels ghi_si000380gb_FM10 fm 27 BB CC FF ...
Page 115: ...wc_tx003699gb_FM10 fm 115 Kubota Genset Genset Maintenance ...
Page 122: ...ghi_td000360gb_FM10 fm 122 Technical Data HI750 Notes ...
Page 142: ......