Operation
HI750
4.22
Overtemperature Shutdown
Background
The machine includes two high-temperature shutdown switches. The switches will
shut down the machine if it experiences an overtemperature condition. During an
overtemperature condition, the fault indicator
(a)
on the control panel will illuminate.
The reset switches must be reset in order for the machine to return to operation.
Requirements
■
Machine cool
Procedure
Perform the procedure below to reset the high temperature reset switches.
1. Allow the machine to adequately cool.
2. Press the overtemperature reset push button
(b)
on the control panel.
3. Restart the machine. See topic
Starting the Machine.
wc_gr010257
b
a