ghi_tx001258gb_FM10.fm
41
HI750
Operation
4.7
Positioning the Machine
The installer must be familiar with all applicable laws, codes, regulations, or other
restrictions regarding installation of Indirect-Fired (IDF) heaters.
CO Alarms
Because this machine produces carbon monoxide (CO), Wacker Neuson
recommends that CO alarms be installed in all structures in close proximity to the
machine. CO alarms provide an extra measure of protection against this poison
that you cannot see or smell.
Install battery-operated CO alarms or plug-in CO alarms with battery backup,
according to the manufacturer’s instructions. CO alarms should be certified to the
requirements of the latest safety standards (UL 2034, IAS 6-96, or CSA 6.19.01).
Test the CO alarm batteries monthly.
Requirements
Position the machine so that:
■
burner exhaust will not enter nearby structures.
■
the machine does not block traffic.
■
the machine is not close to any combustible material or flammable vapor.
■
all of the machine’s access doors/panels may be accessed.
■
power cords do not pose tripping hazards, and so that the power cords cannot
be damaged by machines or other equipment on the job site.
This procedure continues on the next page.
DANGER
Asphyxiation hazard. Exhaust gas from the burner contains carbon monoxide, a
deadly poison you cannot see or smell. Exposure to carbon monoxide can kill you
in minutes.
►
Position the machine so that burner exhaust will not enter any nearby
structures.
WARNING
Fire hazard. Do not move the machine while it is running.
►
Shut down the machine before moving or repositioning it.
WARNING
Fire hazard. Machines positioned on a hill or an incline may slide, break away, or
roll over.
►
Do not position the machine on a hill or an incline.
WARNING
Explosion and fire hazard. Risk of severe injury or death.
►
Do not operate the machine near flammable vapors, fuels, or combustibles.
Summary of Contents for HI750 Series
Page 6: ...ghi_tx001257gb_FM10 fm 6 Foreword HI750 ...
Page 27: ...HI750 Labels ghi_si000380gb_FM10 fm 27 BB CC FF ...
Page 115: ...wc_tx003699gb_FM10 fm 115 Kubota Genset Genset Maintenance ...
Page 122: ...ghi_td000360gb_FM10 fm 122 Technical Data HI750 Notes ...
Page 142: ......
Page 143: ......