wc_tx001396gb_FM10.fm
89
HI750
Burner Setup—Gas
Continued from the previous page.
7. Check the pressure reading on the manometer. See chapter
Technical Data
for
the correct pressure. Adjust the supply gas pressure as needed.
8. After the supply gas pressure has been set, turn off the supply gas.
9. Remove the manometer and the nipple.
10.Re-install the plug.
Result
The supply gas pressure has now been checked and adjusted.