ghi_tx001258gb_FM10.fm
46
Operation
HI750
4.13
Flex Ducting Options
Refer to the chart below for the maximum allowable return and supply duct lengths
for your machine.
NOTICE:
Do not exceed the maximum total lengths specified in the chart.
Exceeding these lengths, or blocking any of the duct openings, constricts the air
flow through the machine and may cause a high-temperature shut-down fault.
MODEL
SUPPLY DUCTING
RETURN DUCTING
Supply
Duct
Adapter
Length
of each
duct
section
(ft)
Maximum duct
sections per
opening
Total
combined
length
Return
Duct
Adapter
Maximum
number of
25 ft duct
secitons
Total
combined
length
Qty
Length
AB XHD
HI770
1 x 20 in.
25
8
200 ft
200 ft
1 x 20 in.
8
200 ft
1 x 16 in.
25
6
150 ft
150 ft
2 x 12 in.
25
3
75 ft
150 ft
HI110
12 in.
25
1
25 ft
25 ft
Return ductwork not available.
HI200
14 in.
25
1
25 ft
25 ft
HI300
3 x 16 in.
25
1
25 ft
25 ft
HI300
HD
4 x 12 in.
25
2
25 ft
50 ft
HI400
D/G
1 x 20 in.
25
4
100 ft
100 ft
1 x 20 in.
4
100 ft
2 x 16 in.
25
2
50 ft
100 ft
3 x 12 in.
25
1
25 ft
75 ft
HI750
HI900
HI1000
2 x 20 in.
25
6
150 ft
300 ft
2 x 20 in.
4
100 ft
3 x 20 in.
25
9
225 ft
675 ft
3 x 16 in.
25
3
75 ft
225 ft
4 x 12 in.
25
1
25 ft
100 ft
HIF690
1 x 20 in.
25
4
100 ft
100 ft
1 x 20 in.
4
100 ft
HIF600
1 x 20 in.
150
6
150
150
1 x 20 in.
1
25 ft
1 x 16 in.
100
4
100
100
2 x 12 in.
100
4
200
200
HIF1200
2 x 20 in.
25
8
15 ft
300 ft
1 x 20 in.
4
100 ft
2 x 16 in.
25
2
50 ft
100 ft
4 x 12 in.
25
1
25 ft
100 ft
Summary of Contents for HI750 Series
Page 6: ...ghi_tx001257gb_FM10 fm 6 Foreword HI750 ...
Page 27: ...HI750 Labels ghi_si000380gb_FM10 fm 27 BB CC FF ...
Page 115: ...wc_tx003699gb_FM10 fm 115 Kubota Genset Genset Maintenance ...
Page 122: ...ghi_td000360gb_FM10 fm 122 Technical Data HI750 Notes ...
Page 142: ......
Page 143: ......