ghi_tx001258gb_FM10.fm
45
HI750
Operation
4.12
Suggested Venting
The Installation of Venting to Natural Gas and Propane equipped models shall
conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code ANSI Z223.1/NFPA 54 and the Natural Gas and Propane Installation
Code, CSA B149.
When installing vents:
■
Do not use B-vent exhaust pipes to vent an oil burning machine. Contact
Wacker Neuson Product Support for recommended alternatives.
■
Adhere to all local and national codes.
■
Adhere to all fire prevention regulations.
■
Consult all appropriate governing bodies or local contractor for venting and
fresh air requirements. Make sure that the room or building to be heated has
sufficient ventilation to ensure that the machine has enough air to function
properly.
■
Position the machine in a manner that avoids excessive vent bends (elbows),
and long horizontal runs.
■
Keep air inlets and outlets free from obstruction. Ensure that there are no bulky
objects or sheets/covers near or on the machine.
■
Route the venting pipes in a manner that avoids flammable materials.
■
Route the venting pipes in a manner that avoids contact with people.
■
When the machine is connected to a flue pipe, the flue pipe shall terminate in a
vertical section at least two feet long. Sufficient draft shall be created to assure
safe and proper operation of the machine (minimum -0.02 in. w.c.).
DANGER
Asphyxiation hazard. Exhaust gas from the burner contains carbon monoxide, a
deadly poison. Exposure to carbon monoxide can kill you in minutes.
►
Never run the machine indoors or in an enclosed area unless the machine is
vented properly according to local and national codes.
Summary of Contents for HI750 Series
Page 6: ...ghi_tx001257gb_FM10 fm 6 Foreword HI750 ...
Page 27: ...HI750 Labels ghi_si000380gb_FM10 fm 27 BB CC FF ...
Page 115: ...wc_tx003699gb_FM10 fm 115 Kubota Genset Genset Maintenance ...
Page 122: ...ghi_td000360gb_FM10 fm 122 Technical Data HI750 Notes ...
Page 142: ......
Page 143: ......