wc_tx001396gb_FM10.fm
88
Burner Setup—Gas
HI750
8.8
Checking the Supply Gas Pressure
Requirements
■
Machine shut down
■
Supply gas turned off
■
Manometer
■
Nipple
Checking
pressure
Perform the procedure below to check and adjust the supply gas pressure.
1. Shut down the machine and allow it to cool.
2. Close the supply gas shutoff valve.
3. Remove the plug
(a)
from the Tee fitting using a hex key.
4. Install a nipple
(b)
into the Tee fitting.
5. Connect the hose of the manometer
(c)
to the nipple.
6. Open the supply gas shutoff valve.
This procedure continues on the next page.
WARNING
Explosion and fire hazard. When combined with air, the gas used for this burner is
explosive. Explosions can cause severe injury or death.
►
Close the supply gas shutoff valve before continuing with this procedure.
►
Extinguish all sources of ignition before continuing this procedure.
a
ghi_gr007058
b
ghi_gr007059
c
ghi_gr007060