Display screen
Explanation
Int. output OFF/ON
Cylinder primary pump
Heating circuit pump OFF/ON If an external extension or extension kit for one
heating circuit with mixer is installed
Central fault message OFF/
ON
If an external extension is installed
Mixer OPEN/CLOSE
If an extension kit for one heating circuit with
mixer is installed
Various languages
The respective languages can be selected as
permanent display language with
d
Vitosolic 100
Select the required scan with
a
or
b
.
Display
Explanation
AH
Solar energy in kW/h
CL
Collector limit temperature
CN
Minimum collector temperature
CX
Maximum collector temperature
SX
Maximum DHW cylinder temperature
TC
Collector temperature
TS
Cylinder temperature
T3
Temperature sensor 3
VN
Software version
Scanning operating conditions and sensors
(cont.)