Maximum collector temperature CX
Delivered condition: CX 120.0
≙
120 °C
Setting
range
Description
CX 100.0
–
CX 190.0
The solar circuit pump is switched ON (collector cooling) when
this temperature (solar circuit idle, maximum cylinder temperature
has been reached) is exceeded.
For this, the cylinder temperature can exceed the maximum cylin-
der temperature "SX", but no higher than 90 ºC (safety shutdown).
Minimum collector temperature CN
Delivered condition: CN 10.0
≙
10 °C
Setting
range
Description
CN -10.0
–
CN 90.0
Minimum starting temperature that must be exceeded before the
solar circuit pump can start. This prevents the pump starting too
frequently.
This function is disabled at CN = 10 ºC.
-10.0 to + 9.9 ºC for frost protection
10.1 to 90 ºC for minimum temperature function
Maximum cylinder temperature FN
Delivered condition: FN 1
Setting
range
Description
FN 0
Maximum cylinder temperature control disabled; the solar circuit
pump is controlled in accordance with the selected starting and
stopping temperature differential
FN 1
Maximum cylinder temperature control enabled
FN 2
Maximum cylinder temperature control disabled; return cooling
function enabled
FN 3
Maximum cylinder temperature control enabled without priority;
collector cooling function enabled
Further details regarding the individual steps
(cont.)
63
Commissioning, inspection, maintenance
5592
883
GB
Service
Summary of Contents for VITODENS 343-F WS4A
Page 137: ...Parts lists cont 137 Parts lists 5592 883 GB Service ...
Page 138: ...Parts lists cont 138 Parts lists 5592 883 GB ...
Page 139: ...Parts lists cont 139 Parts lists 5592 883 GB Service ...
Page 140: ...Parts lists cont 140 Parts lists 5592 883 GB ...
Page 141: ...Parts lists cont 141 Parts lists 5592 883 GB Service ...
Page 142: ...Parts lists cont 142 Parts lists 5592 883 GB ...
Page 151: ...151 5592 883 GB ...