Maximum flow rate FX
Delivered condition: FX 3.0
≙
3.0 l/min
Setting
range
Description
FX 0.0
–
FX
20.0
Select the flow rate in accordance with the installed collectors
(see Vitosol service instructions)
Heat transfer medium ME
Delivered condition: ME 1 (never adjust)
Setting
range
Description
ME 0
Water
ME 1
Tyfocor G-LS
Manual mode MM
Delivered condition: MM 4 (automatic mode)
Setting
range
Description
MM 0
Relay 1 and 2 OFF
MM 1
Relay 1 (solar circuit pump) ON, relay 2 OFF
MM 2
Relay 1 (solar circuit pump) OFF, relay 2 ON
MM 3
Relay 1 (solar circuit pump) ON, relay 2 ON
MM 4
Automatic mode
Instructing the system user
The system installer must hand the operating instructions to the system user
and instruct him/her in the operation of the system.
Scanning and resetting the "Service" display
The red fault indicator flashes when the limits set via coding address "21" and
"23" have been reached.
"Service"
flashes in the programming unit display:
Further details regarding the individual steps
(cont.)
64
Commissioning, inspection, maintenance
5592
883
GB