Coding in the delivered condition
Possible change
65:...
Information regarding
the type of diverter
valve (not adjustable)
65:0
Without diverter valve
65:1
Diverter valve by
Viessmann
65:2
Diverter valve by Wilo
65:3
Diverter valve by Grund-
fos
67:40
3. Set DHW value
67:0
to
67:60
Set DHW value adjusta-
ble from 0 to 60 °C
6C:100
Set speed; internal cir-
culation pump with
DHW heating 100 %
6C:0
to
6C:100
Set speed adjustable
from 0 to 100 %
6F:...
Maximum output for
DHW heating; defaulted
by the boiler coding
card
6F:0
to
6F:100
Max. output during DHW
heating adjustable from 0
to 100 %
71:0
DHW circulation pump:
According to time pro-
gram: "ON" (separate
switching times are
possible for the Vitotrol
300)
71:1
"OFF" during DHW heat-
ing to the first set value
71:2
"ON" during DHW heat-
ing to the first set value
72:0
DHW circulation pump:
According to time pro-
gram: "ON"
72:1
"OFF" during DHW heat-
ing to the second set
value
72:2
"ON" during DHW heat-
ing to the second set
value
73:0
DHW circulation pump:
According to time pro-
gram: "ON "
73:1
to
73:6
During the time program
1x/h "ON" for 5 min
up to 6x/h "ON" for 5 min
73:7
permanently "ON"
General
76:0
Without LON communi-
cation module
76:1
With LON communication
module; automatic recog-
nition
Code 2
(cont.)
74
Coding
5592
883
GB
Summary of Contents for VITODENS 343-F WS4A
Page 137: ...Parts lists cont 137 Parts lists 5592 883 GB Service ...
Page 138: ...Parts lists cont 138 Parts lists 5592 883 GB ...
Page 139: ...Parts lists cont 139 Parts lists 5592 883 GB Service ...
Page 140: ...Parts lists cont 140 Parts lists 5592 883 GB ...
Page 141: ...Parts lists cont 141 Parts lists 5592 883 GB Service ...
Page 142: ...Parts lists cont 142 Parts lists 5592 883 GB ...
Page 151: ...151 5592 883 GB ...