33
6.6
Transportation and Storage
DANGER!
RISK OF ELECTRICAL SHOCK, GENERAL
Do not install equipment showing any physical damage.
If packaging is damaged, do not accept receipt from the shipper.
CAUTION!
PREVENT EQUIPMENT DAMAGE, PROPER HANDLING
Do not stack nor lay the enclosure on its side.
To avoid possible personnel injury or enclosure damage, do not remove it from the pallet until at the installation site, at the
point of transfer onto the pad.
WARNING!
RISK OF INJURY, FROM UNSECURED ENCLOSURE
Do not push or lean against an unsecured (unbolted) enclosure as it may tip over causing bodily injury.
Do not pull cables, terminate cables, install or place any batteries or rectifiers until enclosure has been secured onto a pad.
Use caution when opening and closing the front door to an enclosure not secured onto a pad.
CAUTION!
PREVENT EQUIPMENT DAMAGE, FROM CONDENSATION
Until the enclosure is turned up for service, the bags of desiccant shipped with the enclosure must remain in the enclosure to
prevent condensation.
Once service is in-place, remove the desiccant.
Use lifting equipment, such as a crane or forklift, appropriately rated for the weight of the load to move the enclosure.
When moving an enclosure with a forklift, make sure that the fork is of sufficient length for the pallet size (48” minimum) and capable
of lifting 4,000 lbs (1814 kg).
For long-term storage, enclosure and packaging should be kept dry and not be exposed to temperatures outside the range of -10
°
C
(14
°
F) to +40
°
C (104
°
F). Once packaging has been discarded and enclosure has been securely placed on a pad or platform, the
enclosure may be exposed to conditions from –40
°
C (-40
°
F) to +52
°
C (126
°
F).
Desiccant has been included for the enclosure to prevent condensation in the interior. If the enclosure is to be stored for a period of 3
months or greater, the desiccant should be inspected monthly, and if necessary replaced. Alternatively, a small heat source, such as a
100 W incandescent light bulb, may be securely and safely placed into the enclosure as a continuous source of heat. The desiccant
bags are to be discarded once the enclosure is in service.
For short-term storage, the enclosure should not be exposed to temperatures that exceed the temperature range of –40
°
C (-40
°
F)
to +70
°
C (158
°
F).
NOTE!
The enclosure is shipped in protective packaging on a wooden pallet. Batteries (if ordered) and rectifiers will be
shipped on a separate pallet.
6.7
Unpacking the Enclosure at the Installation Site
CAUTION!
Do not open the door with door mounted climate control systems unless the enclosure is secured to the pallet or
the mounting surface. An unsecured enclosure is unstable and could tip over causing injury or equipment damage.
Procedure
1.
Inspect the exterior packaging for damage. If being received and exterior has been damaged, do not accept shipment.