OPERATORS MANUAL
ORION II
Orion II 500-10000 Operators
Page 15 of 95
Manual Part no: DOMAON0100 Issue A
April 2008
4 TECHNICAL DATA
4.1 NOMINAL FLOWRATES IN SERVICE
Nominal flows are based on operation at 15
C, 500mg/l TDS, 20mg/l CO2 and SDI <3
Actual flow rates are site specific and will be defined in the Design Qualification for the plant,
but in general will depend on
–
Operating temperature
Feed water analysis
Size of unit
Required product water specification
System recovery
4.1.1 Single Pass RO only
MODEL
500
1000
2000
4000
6000
8000
10000
Feed
I/h
667
1333
2667
5333
8000
10667 13333
Product
l/h
500
1000
2000
4000
6000
8000
10000
RO Concentrate to Drain
I/h
167
333
667
1333
2000
2667
3333
RO Concentrate Recycle
I/h
1180
530
860
4250
3520
4000
5260
Recovery
%
75
4.1.2 Twin Pass RO only
MODEL
500
1000
2000
4000
6000
8000
10000
Feed
I/h
990
1780
3210
6350
8940
11920 14530
Product
l/h
500
1000
2000
4000
6000
8000
10000
RO Concentrate to Drain
I/h
490
780
1210
2350
2940
3920
4530
Pass 1 RO Conc Recycle
I/h
900
900
200
4600
4800
1800
1200
Pass 2 RO Conc Recycle
I/h
890
1170
1270
4700
4700
6270
6350
Recovery
%
50
– 70