background image

7

20 

60

804 

U

S

 (

04.

11

AL

WARNING

Improper 

installation,

adjustment, alteration, service or maintenance can cause
injury  or  property  damage.  Refer  to  this  manual.  For
assistance or additional information consult a qualified
installer, service agency or the gas supplier.
Upon completion of the installation, these instructions
should be handed to the user of the appliance for future
reference.
In  the  Commonwealth  of  Massachusetts  this  product
must be installed by a licensed plumber or gas fitter.

I N STALLATION  AN D  OPE RATI NG  I N STR UCTION S  FOR  AUTOMATIC
INSTANTANEOUS  TYPE  WATER  HEATERS  FOR  USE  WITH  NATURAL  AND
LIQUEFIED  PETROLEUM  GAS

MODEL 125HX LP and 125HX NG

(Flow Modulated with Electronic Ignition)

Suitable for heating potable water only

Not approved for space heating purposes

Intended for variable flow applications with steady cold water inlet temperatures.

WARNING

If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage,
personal injury or death.

FOR YOUR SAFETY

Do  not  store  or  use  gasoline  or  other  flammable,
combustible or corrosive vapors and liquids in the vicinity
of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

-

Do not try to light any appliance.

-

Do  not  touch  any  electrical  switch;  do  not  use  any
phone in your building.

-

Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.

-

If  you  cannot  reach  your  gas  supplier,  call  the  fire
department.

-

Installation  and  service  must  be  performed  by  a
qualified installer, service agency or the gas supplier.

TABLE OF CONTENTS

Specifications ............................................................................. Page 3
Rules for safe operation ........................................................... Page 5
Locating the Heater .................................................................. Page 5
Combustion Air Requirements ............................................... Page 6
Mounting the Heater ................................................................. Page 6
Venting the Heater ..................................................................... Page 7
Gas Connections ...................................................................... Page 9
Gas Piping ................................................................................ Page 10
Water Connections ................................................................. Page 11
Safety before turning on the heater ..................................... Page 11
Operating instructions ........................................................... Page 12
Setting water temperature .................................................... Page 12
Maintenance & Service ........................................................... Page 13
Trouble  Shooting ..................................................................... Page 13
Electrical Diagram .................................................................... Page 15
Diagram of 125HX .................................................................. Page 17
Interior components diagram ............................................... Page 18
Parts  List ................................................................................... Page 19
Flowchart ................................................................................. Page 20
Warranty .................................................................................... Page 21

Summary of Contents for 125HX

Page 1: ...sing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follo...

Page 2: ...f the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR SAFETY Do not store or use gasoline or other flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use ...

Page 3: ... will not exceed the heating capacity of the heater On Off Switch to activate system Red LED indicator flashes with low water pressure Green LED indicator main burner operation BOSCH is constantly improving our products therefore specifications are subject to change without prior notice 125 HX LP and 125 HX NG Specifications Gas Input max 117 000 Btu hr min 28 000 Btu hr Water Connection Thread fi...

Page 4: ...INIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW MODEL 125HX MODEL 125 HX TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 VENT DIAMETER 5 ...

Page 5: ...control which has been underwater PROPER LOCATION FOR INSTALLING YOUR HEATER Carefully select the location of your new heater For your safety and for proper heater operation you must provide an abundant supply of combustion air and a proper venting Fig 1 Water heater drain plug The heater may still operate even when improperly vented It will however be less efficient and could eventually damage th...

Page 6: ...ng 2000 Btu hr if all air is taken from the outside by horizontal ducts 4000 Btu hr if all air is taken from the outside by direct openings or vertical ducts Or the confined space must be provided with one permanent opening or duct that is within 12 inches of the ceiling of the enclosure This opening must have a minimum free area of one square inch per 3000 Btu hr if all air is taken from the outs...

Page 7: ...s stamped with a number 79 for LPG and 120 for Natural Gas Fig 2 Mounting the Heater WALL STUDS 1 X 4 SPACE BOARD SUPPORT BOARD 13 Fig 3 Incandescent Particle Tray Illustration The incandescent particle tray shipped loose in the carton with the water heater must be attached at the bottom of the water heater front cover at the time of installation Use the screws provided See figure 3 SCREWS INCANDE...

Page 8: ...ter heater to a masonry chimney the following connector guidelines must be followed for safe and proper operation An approved gas vent connector must be attached to the top of the water heater and rise vertically at least 12 before entering into an approved gas vent connector elbow Any gas vent section that is greater than 45 degrees from the vertical is considered horizontal If a horizontal vent ...

Page 9: ...the gas lines or malfunction of the supply system the gas valve and regulator must be checked for safe operation Make sure that the regulator vent is protected against blockage When your connections are made check for gas leaks at all joints not just the ones you made Apply some soapy water to all gas fittings and gas valve Soap bubbles are a sign of a leak NOTE Do not apply soap solution to the p...

Page 10: ...l length of piping and then adding 5 ft for every elbow or T to the actual length Use the charts below to determine the pipe diameter necessary to accommodate the BTU demand of the unit If there are more gas drawing appliances on the line size according to the maximum amount of BTU demand Follow boxed numbers for piping just one 125 HX example 3 4 B I Natural Gas pipe for 30 ft will handle 152 000...

Page 11: ...runs as short as possible When facing the heater the cold water inlet will be on the right and the hot water outlet on the left Although water piping throughout the building may be other than copper copper or galvanized piping should be used when connecting to the heaters male NPT flex connectors follow local codes if more stringent Plastics or other PEX type plumbing line materials are not suitab...

Page 12: ...icator light is flashing this is a warning that the water pressure is not enough to ignite the main burner 6 Turn the hot water faucet on to the minimum flow rate required to activate the heater The automatic ignition system first ignites the safety pilot burner which then ignites the main burner in about 4 seconds 7 The green LED indicator is on when the main burner is on 8 The pilot flame will e...

Page 13: ...have yellow flames while others have good flames it is likely that dust lint or spider webs have partially clogged the burner venturis To clean the burners contact a gas service person Mineral Scale Build up The 125 HX heater when operated at lower temperature settings does not accumulate mineral build up If however the heater is used at the higher temperature settings and the water has a high min...

Page 14: ...and component parts must be totally free of dirt In hard water areas mineral deposits can eventually 3 5 years in hard water areas corrode the water valve parts to a point where they will need replacing Any sign of moisture or corrosion at the joint of the water valve and the gas valve is a sign that the water valve components need to be serviced immediately 7 Poor circuit connections at the ECO o...

Page 15: ...is mixing with the hot water between the 125 HX and the outlet Compare water temperature at outlet of the 125 HX hold the 125 HX outlet pipe with your hand and at the tap If these two are very different check for mixing valve or plumbing crossover see NO SPARK AT THE PILOT paragraph 2 5 Parts in water valve are dirty or damaged which will prevent the gas valve from being fully opened Water valve m...

Page 16: ... reduce such hot water temperature in the event of any temperature instability with the use of a temperature balance shower valve refer to shower valve manufactures instructions for internal adjustment setting Adjustments should be made to the hottest setting in the shower valve Additionally the temperature control of the heater can be adjusted to produce a more comfortable hot water temperature S...

Page 17: ...ner manifold gas pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 LED failure indicator 7 on off switch 8 LED operation indicator 9 Water valve 10 Temperature adjustment selector 11 Gas inlet gas pressure test nipple 12 Hose 3 1 4 10 11 2 9 8 6 7 5 12 6 720 606 804 10 1AL ...

Page 18: ...18 6 720 606 804 Fig 15 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Page 19: ...7 Pilot electrovalve 8 708 501 249 18 Burner electrovalve 8 708 501 250 19 O ring 8 700 205 023 20 Hydro generator 8 707 406 043 21 Cold water pipe 8 700 705 947 22 Outlet flex hose 8 700 703 139 23 Washer 8 700 103 658 24 Water valve 8 707 002 649 25 Water valve cover 8 705 500 101 26 Diaphragm 8 700 503 053 27 Water inlet filter 8 700 507 001 28 Water valve selector screw 8 708 500 289 29 Volume...

Page 20: ...20 6 720 606 804 Fig 16 Flow chart of 125 HX ...

Page 21: ... in normal use and service within the applicable periods specified below in accordance with the terms of this warranty The CEC replacement will be warranted for the unexpired portion of the original warranty This warranty will be valid only for water heaters in possession of the original purchaser as recorded on the warranty card The Heat Exchanger If the heat exchanger fails within twelve 12 year...

Page 22: ...22 6 720 606 804 ...

Page 23: ...23 6 720 606 804 ...

Page 24: ...ield Vermont 05673 Phone 800 642 3111 Fax 802 496 6924 www controlledenergy com tech techsupport controlledenergy com 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V E S R A E Y 2 Y R E V E S R A E Y 5 3 Y R E V E E V L A V R E T A W E T A C I R B U L E V L A V R E T A W D L I U B E R N E E R C S R E T L I F R E T A W T C E P S N I Y L B M E S S A T O L I P T C E P S N I Y L B M ...