OPERATORS MANUAL
ORION II
Orion II 500-10000 Operators
Page 78 of 95
Manual Part no: DOMAON0100 Issue A
April 2008
7 PLANT OPERATION
7.1 OPERATING MODES
The plant is designed to operate either continuously or on a stop start basis and can be started and
stopped by an Operator using a green access key. Any alarms which appear should be investigated
and re-set using the instructions on the HMI screen.
7.2 STARTUP AND SHUTDOWN
The following is the routine start-up procedure once the system has been installed and
commissioned.
Switch on compressed air supply to the system and regulate to 6 bar using the regulator inside
the right hand side control cabinet.
Switch on feedwater supply to the unit. A minimum of 4 bar is required for operating the
softeners.
Ensure the manual valves fitted to the relevant options are in the OPEN position.
V10-01, V10-04, V10-06
V11-04, V11-06,
V12-01, V12-07
V13-01
V14-01
V30-03
V45-03
V50-03
V60-01, V60-02
V70-02
V71-02, V71-03
V72-02
V80-02
Ensure tank drain valve V30-02 is in the closed position.
Switch on the power to the system. The HMI screen will boot up after about 30 seconds and
automatically load the relevant operating programme, (factory set) and then the graphical