# of Streams:
From 1 to 8 streams. Pressing the zoom function, displays the Bandwidth allocated per Stream:
Note
: The total bandwidth for all streams cannot exceed 100%.
Throughput Setup - General
Throughput Setup - Stream BW Overview
7.3.1.2 Control
Control button:
Overview:
Configures the loop-up and loop-down commands necessary to control the far end unit. The user is allowed to
configure the commands manually or automatically.
Manual selection:
user must input the destination MAC/IP address of the far end device including the command
type
Automatic selection:
User must select from a list of discovered devices to loop-up/down.
In automatic mode no configuration is necessary - user only has to select the "discovered" far end device to
control.
7.3.1.3 Per Stream Configurations
Please note that for any of the per stream configurations (Header, Traffic, and Error Injection), a stream number will
be displayed. The user must select each stream number separately to configure the respective parameters. Select
the stream # by tapping the stream number box at the top right hand side of the screen.
Header Settings (Per Stream Configurations)
Profile:
Load a previously configured test profile or create a new profile from the existing settings.
Test:
Select the test layer. Options Layer 2 and Layer 3.
Frame Type:
Select the Ethernet frame type. The options are 802.3 Raw (IEEE 802.3 frame without LLC),
802.3 LLC (IEEE 802.3 frame with LLC header), 802.3 SNAP (IEEE 802.3 frame with SNAP header), and
Ethernet II (Dix). Note: The 802.3 Raw frame type is not available when Layer 3 is selected.
VLAN:
Off, 1 tag, 2 tags, or 3 tags. The user will be able to configured up to 3 VLAN tags (VLAN stacking,
for Q-in-Q applications).
MPLS:
Off, 1 tag, 2 tags, or 3 tags. MPLS tag configuration is only available when the MPLS option is
MX100/120 e-Manual D07-00-004 Rev A04