83
Appendix B: Tables
Initial filament current values apply for 0.25mm (0.010 in.) tungsten wire.
Recommended Initial Filament Current Limits
Recommended Current Filament Current Limits
Discharge current limit is selectable only on the MPS-3000 CE HC power
supply.
Recommended Discharge Current Limits
Table B.1: Circular Ion Source
Circular Ion Source
Size (in cm)
Initial Cathode
Current
Initial Neutralizer
Current
2.5
3.5A
3.5A
3
3.5A
3.5A
5
3.5A
3.5A
Table B.2: Circular Ion Source
Circular Ion Source
Size (in cm)
Cathode
Current Limit
Neutralizer
Current Limit
PBN Current
Limit
2.5
6.5A
6.5A
6.5A
3
6.5A
6.5A
6.5A
5
6.5A
6.5A
6.5A
Table B.3: Recommended Discharge Current Limits
Circular Ion Source
Size (in cm)
Discharge Current
Limit
2.5 HP or LP
3.00A
3
2.50A
5
4.50