20
Interlock Connector (DB9) (8)
Output cable connection of the external interlock circuit.
Emission Fuse (F8) (9)
Protects the neutralizer emission circuitry.
Controller Board Switch Definitions
The power supply is designed to allow the user to select several different
operating options. The options are selected and programmed into the
power supply by the appropriate positioning of switches located on the
controller board. To change switch settings refer to
“Replacing the
Switches” on page 68
.
•
The on position indicates that the switch is towards the top of
the board.
•
The off position indicates that the switch is towards the bottom
of the board.
Switch Settings for Switch Bank #1
SW1-1:
For factory use only. Do not change the positions of this switch.
SW1-2, SW1-3:
Power supply identifier. Selects a number for identification of a power
supply through the computer. When more than one power supply is
part of a computer-controlled system, each power supply may be
assigned a different identification number.
SW1-4:
Neutralizer Fault Switch
MPS-3000 CE FC
ID #
SW 1-2
SW 1-3
1
On
On
2
On
Off
3
Off
On
4
Off
Off
Summary of Contents for MPS-3000 CE
Page 1: ...MPS 3000 CE Power Supply Technical Manual 425964...
Page 2: ...MPS 3000 CE Power Supply Technical Manual...
Page 90: ...86 Filament Cathode with Filament Neutralizer or PBN Option...
Page 91: ...87 Hollow Cathode and HCN 7 pin or 2 x 4 pin feedthrough...
Page 92: ...88 Hollow Cathode and Hollow Cathode Neut 6 pin feedthrough...
Page 93: ...89 Filament Cathode with Filament Neutralizer or PBN Option...
Page 94: ...90 3cm Source Filament Cathode and Filament Neutralizer...
Page 95: ...91 3cm Source Hollow Cathode and Hollow Cathode Neutralizer...