DS1097-010
52
3.7.3
IO SENSOR ALARM NOTIFICATION
For this Menu page please read the description under the following pictures: Now you can perform alarm set based on
different status.
Here follow a short Notification description:
•
Alarm In:
allow you select one desired Alarm No.
•
Alarm Type:
allows you select the three options – NO (Normal Open), NC (Normal Close) and OFF. Set to “Normal
Open”, I/O status Alarm will be activated while sensor is ON; set to “Normal Close”, I/O status alarm will be activated
while sensor is OFF; set to “OFF”, I/O status alarm will not be triggered.
•
Buzzer:
you can set how long the buzzer will sound when sensor alarm is detected (OFF, 10sec, 20sec, 40sec,
60sec);
•
Alarm Out:
allow to match the correct external alarm sensor number.
•
Latch Time:
you can set how long the external sensor alarm will last when sensor alarm is detected (10sec, 20sec,
40sec, and 60sec);
•
Channel:
to allow to match the channel to IO alarm. The channel will be activated when the alarm is detected.
•
Post Recording:
you can set how long alarm record will last when alarm ends (10sec, 30sec, 1min, 2min, 5min).
•
Show Message:
You can set show the icon on the screen when sensor alarm is detected. About icons type please
refer to section “
3.2 - Live Interface and Pop-up Menu
”.
•
Send Email
: Allows you set the alarm images is issued to a specified email (for more information, see section “
3.8.3 -
”).
•
Full screen:
you can set if the video is displayed in full screen mode when Alarm Event is detected.
•
FTP Picture Upload
: send the picture to FTP Server for IO Alarm Event
•
FTP Video to Upload
: send the video to FTP Server for IO alarm Event
•
Picture to Cloud
: send the picture to Cloud Server for IO Alarm Event
•
Video to Cloud
: send the video to Cloud Server for IO Alarm Event
•
Copy:
allow you copy current IO parameters to any other IOs.
•
Default:
allow to restore the Default notification settings.
Alarm Type
Function
Motion/ PIR
When an object moves into motion/PIR detection area, alarm will be triggered. You can adjust
sensitivity level to suit the needs of your actual application environment.
IO Alarm
System can convert alarm signal triggered by external sensor into signal identified by system.
Summary of Contents for 1097/564
Page 95: ...DS1097 010 95 Capture Settings Set the format and the path to save snapshots...
Page 150: ...DS1097 010 150...
Page 151: ...DS1097 010 151...