3.7.1
INTELLIGENT ANALYSIS NOTIFICATION
You can set the Notifications for each Intelligent Analysis Event (PID, LCD, SOD, PD, FD, CC, Sound Detection,
Occlusion Detection).
Here follow a short Notification description:
•
Channel:
this is used to select the channel with which the Intelligent detection function is associated.
•
Buzzer:
you can set if the buzzer will sound and how long when Intelligent event is detected (Disable, 10sec, 20sec,
40sec, 60sec).
•
Alarm Out:
allow to match the correct external alarm sensor number.
•
Latch time:
you can set how long the external sensor alarm will last when Intelligent Event is detected (10sec, 20sec,
40sec, and 60sec).
•
Record Channel:
this is used to select the channels to be recorded following the intelligent event detected by the
HVR from the list shown.
•
Post Recording:
you can set how long alarm record will last when alarm ends (10sec, 30sec, 1min, 2min, 5min).
•
Show Message:
You can set show the icon on the screen when Intelligent alarm is detected. About icons type please
refer to section “
3.2 - Live Interface and Pop-up Menu
”.