C283A83
The configured
Teach Pendant has
no Three-Positional
Enabling Device
The safety configuration
enables the Teach
Pendant’s Three-Positional
Enabling Device, but the
configured Teach Pendant
does not have a Three-
Positional Enabling Device
a) Check that the correct
Teach Pendant is selected in
the safety configuration
b) Conduct a complete
rebooting sequence
c) Update software
d) Contact your local
Universal Robots technical
support
C283A84
Safety system
Received an invalid Teach
Pendant type in the user
configuration
C283A85
Automatic
Safeguard Stop Input
disagreement within
the safety system
The input signals are not
switching simultaneously,
or are incorrectly connected
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance
C283A86
Automatic
Safeguard Reset
Input disagreement
within the safety
system
The input signals are not
switching simultaneously,
or are incorrectly connected
a) Ensure both inputs are
properly connected
b) Contact your local
Universal Robots service
provider for assistance
C283A87
Injection-Molding-
Machine-Interface is
connected while it is
disabled in the robot
configuration
If the Injection-Molding-
Machine-Interface is
enabled, it must be
connected. If it is disabled,
it must be disconnected
Disconnect the Injection-
Molding-Machine-Interface or
enable it in the configuration
C283A88
Lost more than
allowed Injection-
Molding-Machine-
Interface safety
packages in a row
a) Check that the Injection-
Molding-Machine-Interface is
properly connected
b) Conduct a complete
rebooting sequence
c) Update software
d) Contact your local
Universal Robots service
provider for assistance