C205A0
Inconsistency
between target
position and speed
C206A
Sanity check failed
C206A0
Target joint speed
does not match
target joint position
change – Base
C206A1
Target joint speed
does not match
target joint position
change – Shoulder
C206A2
Target joint speed
does not match
target joint position
change – Elbow
C206A3
Target joint speed
does not match
target joint position
change – Wrist 1
C206A4
Target joint speed
does not match
target joint position
change – Wrist 2
C206A5
Target joint speed
does not match
target joint position
change – Wrist 3
C207A
Fieldbus input
disconnected
Check fieldbus connections
(RTDE, ModBus, EtherNet/IP
and Profinet) or disable the
fieldbus in the installation.
Check RTDE watchdog
feature. Check if a URCap is
using this feature.
C208A
Debug Assertion
failed
An assert was executed.
Notice: The functionality is
exclusively used for testing
purposes.
C209A
A protective stop
was triggered (for
test purposes only)
A protective stop was
triggered. Notice: The
functionality is exclusively
used for testing purposes.