C283A20
Safety system
Wrong payload mass sent
from the controller
a) Check that the joints are
proper connected
b) Do a Complete rebooting
sequence
c) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C283A21
Safety system
Wrong payload center of
gravity sent from the
controller
a) Check that the joints are
proper connected
b) Do a Complete rebooting
sequence
c) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C283A22
Teach Pendant is
connected while it is
disabled in robot
configuration
If the Teach Pendant is
enabled, it is connected. If it
is disabled, it is not
connected.
Disconnect the Teach
Pendant or enable it in the
configuration.
C283A23
Safety system
Lost several safety
packages in a row from
other safety processor
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C283A24
Safety system
Got several safety packages
too early in a row from other
safety processor
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C283A25
Safety system
Got a ready message from
an unexpected source
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C283A26
Force limitation:
exceeded torque
window
a) Ensure the mounted
payload, TCP and CoG
matches your configuration.
b) Slow down movements
c) Contact your local
Universal Robots service
provider for assistance.
UR5