C210A
Socket is read-only
when the robot is in
local (Teach
pendant) control
Set the robot in remote
control in PolyScope to
enable receiving scripts in
the controller
C211A
Operational mode
changed
C211A0
Disabled
C211A1
Automatic
C211A2
Manual
C212A
Name conflict in
loaded program
C212A1
Name conflict(s)
occurred between
feature names and
program variables
Some feature names and
program variables share the
same name, which may
cause confusion.
Rename the program
variables.
C213A
No Kinematic
Calibration found
(calibration.conf file
is either corrupt or
missing)
Calibration.conf file is
either corrupt or missing
A new kinematics calibration
may be needed if the robot
needs to improve its
kinematics, otherwise, ignore
this message.
C214A
Kinematic
Calibration for the
robot does not
match the joint(s)
The calibration checksum
stored in the
calibration.conf does not
match the values from the
joint(s)
If moving a program from a
different robot to this one, re-
kinematic calibrate the
second robot to improve
kinematics, otherwise ignore
this message.
C214A1
The Kinematic
Calibration
checksum does not
match the Base
checksum
The calibration checksum
stored in the
calibration.conf does not
match the values from the
joint(s)
If moving a program from a
different robot to this one, re-
kinematic calibrate the
second robot to improve
kinematics, otherwise ignore
this message.
C214A2
The Kinematic
Calibration
checksum does not
match the Shoulder
checksum
The calibration checksum
stored in the
calibration.conf does not
match the values from the
joint(s)
If moving a program from a
different robot to this one, re-
kinematic calibrate the
second robot to improve
kinematics, otherwise ignore
this message.
UR5
140
Service Manual
7. Troubleshooting