
C267A
Bootloader error
Corrupted firmware
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
C267A0
to
C267A11
Critical error on
Bootloarder
A critical error occurred
during Firmware upgrade.
Hardware configuration
mismatch.
Check your image, SCB, MB
or TP for bootloader fixes.
Update software.
C268A0
Special Command
Received unhandled
command cmd
C268A1
Special Command
Recieved Set Zero
Command at too high speed
C269A
Transceiver
Fieldbus transmitting and
receiving of information
failed
C269A0
to
C269A70
Transceiver
C271
Low-level runtime
thread
Process running behind
a) Check that the program
and client interface is not
taking unnecessary
resources.
C271A1
to
C271A5
Runtime is too much
behind
One of the threads might be
using too much time
Consider using a Wait or
sync() to split long program
sequences that do not move
the robot.
C272A
Missing joint
calibration
C272A0
to
C272A6
Critical error – the
calibration is
missing
calibration could not be
loaded
a) Update software
b) Contact your local
Universal Robots service
provider for assistance.
C273A
Cross monitoring
C273A0
Critical error
A critical disagreement
error occurred in the safety
system
a) Do a Complete rebooting
sequence
b) Update software
c) Contact your local
Universal Robots service
provider for assistance.
Service Manual
145
UR5
7. Troubleshooting
C
o
p
yr
ig
h
t
©
2
0
0
9
–
2
0
2
1
b
y
U
n
iv
e
rs
a
l
R
o
b
o
ts
A
/S
.
A
ll
ri
g
h
ts
re
s
e
rv
e
d
.