![background image](http://html1.mh-extra.com/html/united-states-stove/ashley-ag30fp/ashley-ag30fp_manual_4498711008.webp)
-8-
STEP 1
Remove the five (5) machine screws attaching the
back cover plate to the rear of the appliance.
STEP 2
Remove the four (4) machine screws attaching the
intake chamber cover plate to the intake chamber.
STEP 3
Remove the six (6) machine screws attaching the
firebox exhaust cover to the firebox.
STEP 4
Remove the five (5) machine screws attaching the
cover plate to the top of the appliance.
STEP 5
Remove the four (4) machine screws attaching the
draft hood collar to the intake chamber.
STEP 6
Remove the six (6) machine screws attaching the
intake inner draft hood to the firebox inside top.
Venting
REAR VENT APPLICATION
There are outlets for both top and rear venting. The unused vent exit must have the cover plates in place, and
the cover plates must be removed from the exit according to the instructions below to be used.
When removing and refitting the plates be sure the associated gaskets are undamaged and refitted as required.
NOTE: All components removed from the top vent exit will be reinstalled for the rear vent.