![background image](http://html1.mh-extra.com/html/united-states-stove/ashley-ag30fp/ashley-ag30fp_manual_4498711043.webp)
-43-
BURNER AND PILOT SYSTEM
The burner assembly may be removed for easier access to the
control compartment.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Vacuum all components of the burner system.
• Visually check burner ports for blockage, especially near the
pilot.
•
Visually check pilot light and burner flame pattern when in
operation. Flames should be steady, not lifting or floating.
FAN
WARNING: The appliance area must be kept clear and free from
combustible materials, gasoline and other flammable vapors
and liquids.
WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
Burner Ports
Burner And Pilot System
Burner Orifice
Breakout View
For Clarification
Purposes Only
WARNING: Do not operate with the glass assembly removed, cracked, or broken. Use protective gloves to
handle any broken or damaged glass assembly components.
Do not use substitute materials. Avoid striking or slamming glass assembly. Avoid abrasive cleaner. DO NOT
clean glass while it is hot.
WARNING: Any safety screen, guard, or barrier removed for servicing must be replaced prior to operating.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Disconnect the fans from electrical current and vacuum.
• The bearings are sealed and require no oiling.
VENT SYSTEM
NOTE: If the vent-air intake system is disassembled for any reason, reinstall per instructions provided with installation.
Refer to Installation Section.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Examination of the vent system is required.
•
The flow of combustion and ventilation air must not be obstructed.
GLASS ASSEMBLY
Performed by:
Homeowner
Frequency:
Annually
Action:
•
Prepare a work area large enough to accommodate the glass assembly on a flat, stable surface.
• Remove safety screen and glass frame assembly.
• Clean glass with a soft cloth and a non-abrasive cleaner.
• Reinstall glass assembly and safety screen.
•
Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating
the appliance.
Performed by:
Qualified Service Person
Frequency:
Annually
Action:
• Inspect the glass for cracks, scratches, and nicks.
• Verify the glass assembly is properly intact and not damaged.
• Replace the glass and the assembly as necessary.
• Only Ashley will supply the replacement of glass assembly as a complete unit.