background image

P900806-00

BRT4036TMN-B

BRT4336TMN-B

BRT4536TMN-B

BRT4036TMP-B

BRT4336TMP-B

BRT4536TMP-B

BRT4042TMN-B

BRT4342TMN-B

BRT4542TMN-B

BRT4042TMP-B

BRT4342TMP-B

BRT4542TMP-B

 -  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use 

any phone in your building. 

•  Leave the building immediately.

•  Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-

tions. 

•  If you cannot reach your gas supplier, call the 

fire department.

 -  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury, death, or property damage.

        AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité 

pourrait d’entraîner des blessures graves, la mort 

ou des dommages matériels.

 -  Ne pas entreposer ni utilizer d’essence ni d’autres 

vapeurs ou liquides inflammables dans le voisinage 

de cet appareil ou de tout autre appareil.

 -  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir 

des téléphones se trouvant dans le bâtiment où 

vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de 

gaz depuis un voisin. Suivez les instructions du 

fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, 

appelez le service des incindies.

  -    L’installation et l’entretien doivent être assurés par 

un installateur ou un service d’entretien qualifié 

ou par le fournisseur de gaz.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future 

reference.

Installateur : Laissez cette notice avec l’appareil.

Consommateur : Conservez cette notice pour 

consultation ultérieure.

Decorative Product: Not for use as a heating 

appliance.

NOTICE: Fireplace is not to be operated by a 

thermostat.

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile 

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the 

rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements 

locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque 

signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.

Installation and Operation Instructions

Models

C

US

Report No. F09-143

Ce manuel est disponible en francais, simplement en 

faire la demande. Numéro de la pièce 900806-02.

P/N 900806-00   REV. A   08/2017

Custom Series Decorative B-Vent Fireplaces
Millivolt System

Summary of Contents for Superior Fireplaces Custom BRT4036TMN-B

Page 1: ... de bâtiment Appelez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoiventêtreassuréspar un installateur ou un service d entretien qualifié ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manu...

Page 2: ...ded its installation complies with State and Local Codes and in the absence of these codes complies with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code CSA B149 1 NOTICE Young children should be carefully supervised when they are in the same room as the appliance Toddlers young children and others may be susceptible to accidental burns A physical Ch...

Page 3: ...e fireplace 17 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 18 Do not operate fireplace if any log is broken 19 Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this fireplace WARNING This product contains and or generates chemicals known to the St...

Page 4: ...maged promptly inform dealer or distributor where you purchased the product Safely retain these items for later installation CODES AND STANDARDS These fireplaces comply with National Safety Standards and are tested and listed by PFS Corporation Report No F09 143 to ANSI Z21 50 in Canada CSA 2 22 in both USA and Canada as vented gas fireplaces The installation must conform to local codes or in the ...

Page 5: ...ION INSTALLATION FLUSH INSTALLATION WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need a building permit from your local Building and Safety Commissioner before installing this appliance other wise your insurance co may not cover this appliance CAUTION Donotconnectappliancebeforepressure testing...

Page 6: ... F 22 1 4 566 mm 24 610 mm w o Brick 29 1 4 743mm 31 788 mm w o Brick N 36 915 mm 40 1016 mm V 7 178 mm 7 178 mm G 32 5 8 829 mm 34 864 mm w o Brick 39 1 2 1004 mm 41 1 4 1048 mm w o Brick O 37 940 mm 41 1042 mm W 2 1 4 58 mm 2 1 4 58 mm H 15 3 4 400 mm 16 3 4 426 mm w o Brick 17 3 4 451 mm 18 3 4 477 mm w o Brick P 8 5 8 220 mm 10 1 2 267 mm X 5 127 mm 4 1 2 115 mm GAS RATING NATURAL BRT4036TMN B...

Page 7: ...earances Top View Cross Section CLEARANCES Minimum clearances to combustibles are Back and Sides of Outer Surround 0 0 mm min Drywall to Sides of Front Face Nailing Flanges 0 0 mm min B Vent Surfaces 1 26 mm min Ceiling to Opening 42 1067 mm min Floor 0 0 mm min Perpendicular Wall See Figure 6 Front Service Clearance 3 0 9 M BRT4036TMN B TMP B BRT4336TMN B TMP B BRT4536TMN B TMP B BRT4042TMN B TMP...

Page 8: ...the supply line to the appliance using a 1 2 NPT black iron gas line terminating 2 5 16 above the bottom of the appliance The gas line must be installed through the lower left side access point or alternate access hole in the bottom of the appliance see Figure 16 Page 12 4 Repack insulation around the gas line to cover any remaining open ings in the conduit sleeve Prepare the incoming gas line wit...

Page 9: ...nto a chimney flue serving a separate solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adaptor or a chimney liner system if all are listed inspected and approved by local codes and or building authorities The examples shown in Figure 10 are typical of most B vent instal lations and codes practices A minimum of 3 fee...

Page 10: ...hecking for Spillage Check this area along entire top edge of fireplace opening Smoke or flame should be drawn into appliance opening CHECKING FOR PROPER VENTING After completing and checking electrical gas and vent connections follow the lighting instructions and allow main burner to run for ap proximately 5 minutes Hold a lighted match or cigarette near the top edge of fireplace opening and play...

Page 11: ...WG TYPE CL2 UL 105 C 25 ft length MAXIMUM or equivalent Figure 14 Wall Switch Wiring Diagram WARNING Do not wire remote wall switch to main power supply Standard 120v household current WALL SWITCH INSTALLATION The installation of a wall switch allows you to activate the gas control valve without normal household electricity since valve operates on millivolt current supplied by heat generated by th...

Page 12: ...incoming black iron gas line with teflon tape or pipe joint compound Check with local building codes WARNING Gaslinehookupshouldbedonebyyour gas supplier or a qualified service person WARNING Before you proceed make sure your gas supply is OFF CAUTION Do not kink flexible gas line GAS LINE HOOK UP A manual shutoff valve has been included in the appliance s gas sup ply system You may consider insta...

Page 13: ...nough ember material to cover burner pan material Leave a 1 2 space between pieces Figure 18 Connecting Flexible Gas Line to Millivolt Valve P I L O T ON OFF IN OUT Gas Shutoff Valve Flexible Gas Line Do NOT Kink 1 2 NPT Incoming Gas Line NOTE 1 Wire Connections Not Shown for Clarity 2 1 8 NPT Plugged Tapping Red Surface Indicates For Propane LP Use Only Pilot Adj Inlet Pressure Tap Outlet Pressur...

Page 14: ... area on front of log 2 as shown in Figure 25 As an option to enhance the look of the hearth you may place the volcanic stone provided around front and sides of burner NOTE It is important to ensure proper log placement per the manual when installing these units Verify pilot flame is not obstructed See Inspecting Pilot and Burner Flame Patterns on Page 19 NOTICE Do not put volcanic stone inside th...

Page 15: ... end of log 6 on top of log 2B see Figure 29 As an option to enhance the look of the hearth you may place the volcanic stone provided around front and sides of burner pan NOTE It is important to ensure proper log placement per the manual when installing these units Verify pilot flame is not obstructed See Inspecting Pilot and Burner Flame Patterns on Page 19 INSTALLATION Continued NOTICE Do not pu...

Page 16: ...rm it must be a continuous surface and not on blocks without a solid surface This will prevent the entry of cold air by means of conduction through the total bottom of appliance see Figure 31 CAUTION Air inlet ducts are not to terminate in attic space CAUTION Use only glass doors certified for use with this appliance INSTALLING OPTIONAL GLASS DOOR ACCESSORY NOTE Glass door may be heavy for some in...

Page 17: ...y closed Operating the appliance with the doors partially open can result in improper venting of flue products 6 Repeat the process for the opposite door assembly 7 To adjust doors slide them partially open Using a screwdriver loosen hold down screws in the spring clip see Figure 33 and pivot plate 8 Close both doors until evenly joined at the middle and note the gap at outer edges of face 9 Reope...

Page 18: ...lectric power to appliance 4 Place damper in full open position 5 Fully open glass doors if installed 6 Remove front refractory brick access panel 7 Turn gas control knob clockwise to the OFF position see Figure 36 8 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information column 1 If you don t smell gas go to the...

Page 19: ...ually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circulating air system be kept clean WARNING Turnoffgasandelectricalpowerbefore servicing appliance WARNING Failure to keep the primary air opening s oftheburner s cleanmayresultinsooting and propert...

Page 20: ... independently of the burner on off wall switch it may be due to the operation of this safety limit switch First allow the appliance to cool then reset the safety switch by pressing the red reset button on the back of the switch To access the blocked flue safety limit switch refer to Figure 41 1 To access the blocked flue safety switch remove the two 2 phillips head screws shown in Figure 41 and p...

Page 21: ...defective or too long 2 Thermopile not generating sufficient voltage 1 Check electrical connections 2 See Pilot will not stay lit above Frequent pilot outage 1 Pilot flame may be too low causing safety pilot to drop out 2 Improper venting or excessive blockage 1 Clean and adjust pilot flame for maximum flame impingement on thermopile 2 Have vent system inspected including termination cap Remove an...

Page 22: ...see Gas Line Hook Up Page 12 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or excessive blockage 5 Excessive amounts of embers and pan mate rial 1 Properly locate logs 2 Clean out air holes at burner inlets Periodically repeat as needed 3 Remove blockage or replace burner 4 Have vent system i...

Page 23: ... non approved parts can result in poor performance and safety hazards MODEL CAT NO INTERIOR F3198 BRT4536TMN B White Herringbone F3199 BRT4536TMP B White Herringbone F3202 BRT4542TMN B White Herringbone F3203 BRT4542TMP B White Herringbone F3206 BRT4336TMN B White Stacked F3207 BRT4336TMP B White Stacked F3210 BRT4342TMN B White Stacked F3211 BRT4342TMP B White Stacked F3214 BRT4036TMN B Black w W...

Page 24: ...0 ASSY AIR KIT DOOR 36 1 23 J6900 PLATE OUTSIDE AIR COVER 36E44 6 1 24 J3992 DEFLECTOR SMOKE 1 J4081 DEFLECTOR SMOKE 1 25 J6895 RETAINER REFRACTORY 36E28 2 26 J4054 GRATE ASSEMBLY 1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 31 J7320 CLIP BURNER 1 32 J4769 NUT 10 24 ...

Page 25: ... F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bottom Front White Stacked 1 KEY NO CATALOG NO DESCRIPTION BRT4042 Black Interior BRT4342 White Stacked BRT4542 White Herringbone QTY 11 F3227 Refractory Set White Herringbone 1 11 F3226 Refractory Set ...

Page 26: ... CATALOG NO DESCRIPTION QTY J4096 LOG SET 1 J4246 LOG 9 FIREPIT SPLIT 1 2 J7241 LOG REAR 22 1 3 J4242 LOG 11 75 TOP ROUND 1 4 J4243 LOG 16 TOP SPLIT 1 5 J4244 LOG 13 5 Y TOP SPLIT 1 6 J4245 LOG 11 TOP 1 KEY NO CATALOG NO DESCRIPTION QTY J4097 LOG SET 1 J7242 LOG REAR 27 1 2A J4245 LOG 11 TOP 1 2B J4262 LOG FIRE PIT 15 75 RND Y 1 3 J4244 LOG 13 5 Y TOP SPLIT 1 4 J4261 LOG 15 75 FIREPIT SPLIT 1 5 J4...

Page 27: ... Brass finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 42 Fixed Glass Door Platinum finish OPTIONAL OUTSIDE AIR KITS Optionalkithelpsoffsetthenegativepressureoftenexistingintoday stightlyconstructed homes Negative pressure may occur when other appliances in the home draw on air possi...

Page 28: ...5 PT42 42 Perimeter Trim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1122 PCBM 36 36 Millivolt NG to LP F1123 NCBM 36 36 Millivolt LP to NG F1126 PCBM 42 42 Millivolt NG to LP F1127 NCBM 42 42 Millivolt LP to NG TOUCH UP PAINT KITS F3373 Black touch up paint firebox interior F1882 SCTPSAB Black t...

Page 29: ...isit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the firep...

Page 30: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ __________________________________...

Page 31: ... natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from faulty installatio...

Page 32: ...replace uses Dealer name P900806 00 IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2016 Innovative Hearth Products P N 900806 00 Rev A 08 2017 1508 Elm Hill Pike Suite 108 Nashville TN 37210 ...

Reviews: