PLEASE READ THE FOLLOWING CAREFULLY It is not unusual to have some odor during the first burn. This is due to
the manufacturing process. Please ensure that your room is well ventilated during burn off — open all windows.
It is recommended that you burn your appliance for at least ten (10) hours the first time you use it. Place the fan
switch in the “OFF” position during this time.
WARNING: Never connect this appliance to private (non-utility) gas wells. This gas is commonly known as wellhead
gas.
PRODUCT SPECIFICATIONS
This appliance:
•
has been certified for use with either natural or propane gas. See appropriate data plates.
• is not for use with solid fuels.
• is approved for bedroom or bed sitting room installations.
• must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI
Z223.1/NFPA 54 in the USA, CSA B149.1 in Canada.
• is mobile home approved.
• must be properly connected to a venting system.
• is not approved for closet installations.
• is approved to be vented using DuraVent, BDM, and Olympia components.
The classification “noncombustible material” includes, but is not limited to stone, brick and mortar. Noncombustibles
are safe to overlay the black-painted metal face (including radiant plates) and do not pose a fire hazard. Do not
allow any noncombustible finish material to extend past or interfere with opening.
The classification “combustible material” includes, but is not limited to plywood, drywall and particle board.
Combustible materials may contact the sides, bottom or back of firebox. Do not overlay the black painted face
with combustible materials.
CONTROLS
Product Features
Valve Regulator
Master On/Off Switch
Air Shutter Adjustment
19.
Do not obstruct the flow of combustion and ventilation air in any way. Provide adequate clearances around
air openings into the combustion chamber along with adequate accessibility clearance for servicing and
proper operation.
20.
Do not use if any part has been under water. Immediately call a qualified service technician to inspect and if
needed replace any part of the control system and any gas control which as been under water.
21. Do not operate if any log is broken.
22. Do not use a blower insert, heat exchanger insert, or any other accessory not approved for use with this
appliance.
23. Do not operate with the glass front removed, cracked, or broken. Replacement of the glass should be done
by a licensed qualified service person.
Ball Valve