![background image](http://html1.mh-extra.com/html/united-states-stove/ashley-ag30fp/ashley-ag30fp_manual_4498711011.webp)
-11-
Framing
Attach the two stand-off assembles to the top of the unit using
four 10-32 X 1/2 screws as shown. NOTE: The two stand offs are
located in the firebox. The four 10-32 X 1/2 screws are provided
in the parts bag.
WARNING: The top stand-offs provide the minimum clearance to the header. Use only non-combustible
material in this area for the entire width of the appliance. DO NOT use wood, sheet-rock, etcetera, in this zone.
Top stand-off brackets must be formed and attached prior to positioning into framed opening.
WALL ENCLOSURE ROUGH OPENING
• Framing dimensions should allow for wall covering thickness
and fireplace facing materials. If using a hearth, adjust
the rough opening size as necessary to maintain minimum
clearance requirements.
• If masonry is to be used (optional), prepare the necessary
foundation for the masonry load. When masonry
construction is to be used, a lintel must be used over the
top of the fireplace to support the additional weight.
WARNING: Provide adequate clearances around air openings into the combustion chamber. Provide
adequate clearance in front of the appliance for barrier removal, component access, gas line installation,
service access, etc.
15-1/2” (394 mm)
47-1/4” (1201 mm)
36-1/4”
(920 mm)
Apply a generous amount of high temperature
sealant around the flue outlet.
NOTE: Approved vent system elbows vary in vertical
length. Consult vent manufacturer’s instructions
to determine the elbow dimension used for your
installation. Adjust as necessary to maintain the
required 1” (25mm) clearance from the vent pipe to
combustible material.
Minimum Clearances to Combustible Material
From Appliance To
inches
mm
Top Stand-Offs
0
0
Left And Right Side Stand-Offs
0
0
Back Stand-Offs
0
0
Corners
1/4
6
Front
36
915
Top To Ceiling
51
1295
Sides To Adjacent Sidewall
6
153
Mantel 9 in (229 mm) deep, 10” (254 mm) from appliance top
**DIMENSION SHOWN WITH LISTED DURAVENT ELBOW.
**UNITS SHOWN WITHOUT STAND OFFS FOR CLARITY.