6.2 Alarm Status and Measures
Indication
Alarm Name
Status
CoF
(CoF)
Current offset error
Motor started operation during free-running.
Cause
Measures
Reference
Restarted before the pump
rotation stopped completely.
After the pump stopped rotating, restart operation again.
4.3
If the alarm persists even after restarting, contact to
ULVAC service center.
End of
Document
Indication
Alarm Name
Status
STPo
(STPo)
Step-out detection
Motor step-out was detected.
Cause
Measures
Reference
Occurrence of power outage
Check the electric wiring.
3.6.1
No cooling water flow
Cool this machine once and then flush it with water.
3.5.2
Pump overload
Contact to ULVAC service center.
End of
Document
Faulty ventilation fan
Contact to ULVAC service center.
End of
Document
Ambient temperature is out of
the specification range
Operate at an appropriate ambient temperature.
3.1.3
Unable to rotate due to other
particles.
Contact to ULVAC service center.
End of
Document
Indication
Alarm Name
Status
LF
(LF)
Output open-phase
An open-phase occurred on the inverter output
side.
Cause
Measures
Reference
The power supply wiring is
broken.
Check the power supply wiring for breaks and miss-
wiring.
➡
Install wiring correctly.
3.6.1
Motor failure
Contact to ULVAC service center.
End of
Document
Inverter failure
Contact to ULVAC service center.
End of
Document
Summary of Contents for MS120A
Page 2: ......
Page 10: ......
Page 14: ......
Page 47: ...33 YO20 0938 DI 001 00 Figure 16 I O block diagram for remote control wiring...
Page 65: ...51 YO20 0938 DI 001 00 7 2 External Dimensions Figure 17 External dimensions of MS120A MS120A...
Page 67: ...53 YO20 0938 DI 001 00...
Page 68: ...54 YO20 0938 DI 001 00...
Page 69: ...55 YO20 0938 DI 001 00...