32
YO20-0938-DI-001-00
■
Pin assignment of remote control wiring
Pin assignment
No.
I/O
Item
Specifications
1
IN
Pump Start
CLOSE: Operation
OPEN: Stop
2
IN
Alarm Reset
CLOSE: Reset
3
IN
External Error
CLOSE: Error
OPEN: Normal
4
IN
Spare
Unable to use
5
N.C
6
OUT
Start check
CLOSE: Running
OPEN: Stopped
7
N.C
8
OUT
Alarm
CLOSE: Normal
OPEN: Alarm
9
IN
IN COM
10
N.C
11
N.C
12
N.C
13
IN
External interlock
CLOSE: Normal
OPEN: Interlock
14
IN
External interlock Common
15
OUT
OUT COM
Figure 15:
Pin assignment of remote control wiring
Table 10:
Signal connector specifications
Connector type
D-sub 15-pin female
Applicable connector type
D-sub 15-pin male
Applicable electric wire size
AWG
#
22
* The fitting screw size of the connector is M2.6.