![UIC GSM FlexJet Manual Download Page 48](http://html1.mh-extra.com/html/uic/gsm-flexjet/gsm-flexjet_manual_3277471048.webp)
Page 43
FlexJet Head Assembly
T47541109 Rev. J
TECHNICAL
PUBLICATIONS
This Document Supports Assembly 47541109 Rev. F
Pushing and holding the Set button for more than 2.5 seconds and then
releasing will cause all Incident-Level-Indicator LEDs to turn green. If
this occurs, push the Mode Selector switch to Run Mode and then push
the switch back to Teach.
c.
Push and release the
Set Button
. All Incident-Level-Indicator
LEDs should turn red. Refer to the following diagram.
Set
Button
Mode
Selector
Threshold
Indicators
Operation
Indicator
Incident
Level
Indicators
Up/Down
Selector
L.
D.
ON
ON
RUN
ADJ
T
E
ACH
SE
T
L
EVE
L
OUT
E3
X-
NH1
1
Operation
Mode
Selector
Positions 1 - 7
d.
Turn the vernier knob located on the setup tool until it
compresses the nozzle tip 0.02 inches (0,50 mm).
e.
Push and release the
Set
Button. The red Incident-Level-
Indicator LEDs should extinguish. If the lights flash red, repeat
from step 1 of this section, driving the vernier an additional 0.005
inches (0,127 mm) into the nozzle tip until the lights turn green.
Maximum nozzle tip compression is 0.025 inches (0,635 mm).
f.
Push the
Mode Selector
switch to
Run
Mode
.
g.
Install Spindle Touch-Down Sensor Assembly cover.
3.
Remove the Impact Sensor Setup Tool from the head.
4.
Remove the 10 MPF nozzle from the spindle.
5.
Perform the following procedure to return the selected spindle to the
home position.
a.
Select
Tool # 1
.
b.
In the
Select Outputs:
section of the window, select the
None
button.
c.
Select
STOP_BRAKE
and
STOP_CLUTCH
in the in the
Select Outputs
field.
d.
While holding the Z-Axis pulley in position, select the
Reset
Outputs
button.
e.
Manually move the spindle up to the home position by turning a
Z-Motor pulley.