![UIC GSM FlexJet Manual Download Page 40](http://html1.mh-extra.com/html/uic/gsm-flexjet/gsm-flexjet_manual_3277471040.webp)
Page 35
FlexJet Head Assembly
T47541109 Rev. J
TECHNICAL
PUBLICATIONS
This Document Supports Assembly 47541109 Rev. F
For a GSM2™ platform machine, it is recommended to verify the
sensors for both FlexJet Heads.
Cleaning the Pin Mirrors
Use the following procedure to clean the Pin Mirrors in the Spindle Housings
to help ensure proper touch-down sensor operation.
Prerequisites
Ensure that the following items are available before beginning the procedure.
• From the FlexJet Tool Kit: Several ESD Swabs (cleaning tools) and
the Impact Sensor Setup Tool.
• Isopropyl alcohol or a solution approved for use on sensitive optical
surfaces.
• A flashlight is recommended.
• A Calibration Kit for FlexJet (for spindle height calibration)
Position the FlexJet Head
Move the head to a convenient location.
• For a GSM1™ platform, move the head to a maintenance location
so that the front of the head is accessible.
• For a GSM2™ platform, It may be necessary to select a
maintenance location and use Discrete I/O to move the heads as
seen in the diagram below.
Move this head to the right so
that the IGUS cable lays flat.
Outer Beam
Inner Beam
Move this head to the left and reach around
the outer beam to clean the Pin Mirrors.
Stand on this side of the machine.
Top View of
the GSM2 Platform