21
TM
85809
amounts of top dressing material. The metering gate
opening size is controlled in two calibrations, Lightspread
and Heavyspread. The metering gate stop pull pin on
the side of the metering gate mount must be pulled out
to allow the metering gate to be moved into the larger
opening size for Heavyspread.
Heavyspread Diverter and Diverter Locking Knob:
The Heavyspread Diverter changes the spread
pattern during Heavyspread operation. During
Heavyspread, the diverter should be in the
lowered position, at position B or C. During light
application, the diverter should be locked in the
raised position, at position A.
The diverter can be set in positions other than
fully raised or lowered. Because of the differences
in top dressing material, setting the diverter in a
partially raised or lowered position may correct or “trim”
the spread to achieve the desired results.
Spinner Assembly Tilt Control Handle and Locking
Handle:
The tilt of the spinner assembly
can be changed by moving the tilt control
handle. Total movement is approximately
26° degrees. The tilt angle can be
changed up or down to vary or correct
the width of spread without changing
the speed of the spinner wheels. The
tilt angle of the assembly can be also
be changed to correct for the difference
in hitch heights of different tow vehicles.
The locking handle will keep the spinner
assembly locked into position.
Metering Gate and Metering Gate Adjusting Handle:
The Metering gate regulates
the amount of top dressing
material released from the
hopper. The metering gate is
manually controlled by moving
the metering gate handle.
The marks on the decal are
for reference only, they do
not represent any measured
L=
PRESET SPEEDS
A
B
C
®
TURFCO
CONVEYOR BELT AND SPINNER
SPEED READOUT DISPLAY
CONVEYOR BELT SPEED
SPINNER SPEED
ON/OFF
SWITCH
PRESET
CONVEYOR BELT
AND
SPINNER SPEED
BUTTONS
LOCKOUT BUTTON
DS85809-03
FIGURE 14
ELECTRONIC CONTROL BOX
DESCRIPTION
������������
�����
�������
A
D
B C
F
G
E
H
DS85807-06
DS85808-08
+8°
+12°
+14°
-8°
-12°
+4°
0°
-4°
DS85809-09
A
B
C
Preset Buttons:
The control box is shipped with the
following factory preset speeds:
“A” Factory settings = 85% spinner & 85% Belt
“B” Factory settings = 45% spinner & 45% Belt
“C” Factory settings = 30% spinner & 80% Belt
Speeds are shown in the control box display. The
numbers indicate % of full speed. The factory settings
can be changed to any desired speeds and saved. The
speeds can also be locked to secure any changes.
Spinner Speed Switch:
Manually changes unlocked
factory preset speeds for the spinners in 5% increments.
Functional only when the control box is in an unlocked
mode.
Conveyor Speed Switch:
Manually changes factory
preset speeds for the conveyor in 5% increments.
Functional only when the control box is in an unlocked
mode.
Lockout Button:
Locks or unlocks access to change
factory preset speeds or to allow the user to enter and
change speeds. Also used to gain access to diagnostic
system performance information and to gain access to
change display contrast (brightness).