Operation
Using fragmentation
186
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Enter the second 128 bytes of write data at
RFID write data 0
Ò
Outputs
.
Click
RFID control/status 0
Ò
Outputs
in the navigation bar on the left of the screen.
Enter at
Write fragment No.
the consecutive number of the next fragment to be written
(here:
2
).
Send the Write command: Click
Submit
.
It is written directly if a tag is in the detection range. The data is stored in the TBEN module if
there is no tag in the detection range.
The tag must stay in the detection range until the command is fully executed. The device out-
puts an error message if the tag is removed from the detection range before the command has
been completed.
Fig. 106: Fragmentation – write second fragment