Setting
RFID channels – overview of commands
124
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.8.10
Command: Read/write head identification
The
Read/write head identification
command scans the following parameters of the connec-
ted read/write head:
n
Ident-No.
n
Serial number
n
Hardware version
n
Firmware status
The parameters are contained in the read/write head in the identification record.
Request
Loop counter
See description of the output data, [
Command code
0x0041 (hex.), 65 (dec.)
Read/write head address
See description of the output data, [
Length UID/EPC
Not required
Start address
Start address in the identification record, stated in bytes
Length
Length of the data to be scanned
0: Read complete parameter set
Command timeout
Not required
Write fragment no.
Not required
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0041 (hex.), 65 (dec.)
Length
See description of the input data, [
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
Increases with each read or written UID/EPC
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data, Byte 0...19
Ident No.: ARRAY [0…19] of BYTE
Read data, Byte 20...35
Serial number: ARRAY [0…15] of BYTE
Read data, Byte 36...37
Hardware version: INT16 (Little Endian)
Read data, Byte 38...41
Firmware status: ARRAY [0…] of BYTE: V (0x56), x, y, z (Vx.y.z)
Read data, Byte 42...119
Not required