8.8.4
Command: Write
The
Write
command causes the read/write head to write data to tags in the detection range.
128 bytes are transferred in a write operation by default. Larger data volumes can be
transferred in fragments. If a particular UID or EPC is entered, the read/write head only reads
the appropriate tags. All other tags in the detection range are ignored in this case.
NOTE
With multitag applications enter the UID or EPC of the tag to be written.
NOTE
The command code for fast processing with the loop counter is 0x2004 (hex.) or
8196 (dec.).
Request
Loop counter
See description of the output data, [
Command code
0x0004 (hex.), 4 (dec.)
Memory area
See description of the output data, [
Read/write head address
See description of the output data, [
Length UID/EPC
Enter UID or EPC size in bytes, if a particular tag is to be writ-
ten. The UID or EPC must be defined in the write data. (start
byte: 0). The function of the length of the UID/EPC depends
on the command used.
0: No entry of a UID/EPC for executing the command. Only
one tag can be located in the detection range of the read/
write head.
> 0: EPC length of the tag to be written if an EPC is present in
the write data
-1: NEXT mode: A tag is always only written if the UID/EPC is
different to the UID/EPC of the last read or written tag.
Start address
Start address of the memory area on the tag to be written
(entry in bytes)
Length
Length of the data to be written in bytes
Command timeout
See description of the output data, [
Write fragment no.
1: Using fragmentation
0: Do not use fragmentation
Read fragment no.
0
Write data,
Byte 0…(size of the UID/EPC-1)
UID or EPC of the tag to be written
Write data,
Byte (size of the EPC)…127
Write data