V02.00 | 2020/08
127
8.8.13
Command: Query HF read/write head address
NOTE
The command is only available in HF bus mode.
The interface can query the addresses of all connected HF read/write heads via the
Query HF
read/write head address
command. If a non-bus-compatible read/write head is connected, the
device outputs an error message.
Request
Loop counter
See description of the output data, [
Command code
0x0070 (hex.), 112 (dec.)
Read/write head address
Not required
Length UID/EPC
Not required
Start address
Not required
Length
Not required
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0070 (hex.), 112 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data, byte 0…[number of
the connected read/write heads]
Addresses of the connected read/write heads (uint8_t)
Read data, byte [number of the
connected read/write
heads] ...127
Not required