Setting
RFID channels – overview of commands
136
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.8.17
Command: Set read/write head password
NOTE
The command is only available for applications with UHF tags and the HF tags
TW-R…-M-B146.
The
Set read/write head password
command directly sets a password for write access, read
access or a
Kill
command. The password is stored temporarily in the memory of the read/write
head. After the voltage of the read/write head is reset, the password must be set again in the
read/write head. With UHF applications, the password is stored in the memory of the interface.
The password stored in the read/write head is automatically sent with a
Write
command, a
Read
command or a
Kill
command so that the command can be carried out on a protected tag.
The password function is only available in HF applications in single-tag mode. An error message
is output with multitag applications. For troubleshooting set the
HF: multitag mode
parameter
to
0
:
Multitag mode off
.
Request
Loop counter
See description of the output data, [
Command code
0x0100 (hex.), 256 (dec.)
Read/write head address
See description of the output data, [
Length UID/EPC
Not required
Start address
Not required
Length
Not required
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data, Byte 0...3
Password: ARRAY [0…3] OF BYTE
Write data, Byte 4...127
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0100 (hex.), 256 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Not required