V02.00 | 2020/08
147
8.8.24
Command: Restore UHF read/write head settings
NOTE
The command is only available for UHF applications.
The
Restore settings UHF read/write head
command restores the parameters of a connected
UHF read/write head from a backup (e.g. after a device swap). Type and firmware version must
be identical for both read/write heads. To execute the command, a backup must be created
beforehand via the
Backup settings UHF read/write head
command.
Request
Loop counter
See description of the output data, [
Command code
0x1000 (hex.), 4096 (dec.)
Read/write head address
See description of the output data, [
Length UID/EPC
Not required
Start address
Not required
Length
Not required
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x1000 (hex.), 4096 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Not required