8.2.2.2.

 

Web Configuration 

 

 

Parameter 

Description 

User Settings 

User Name 

Enter the v3 user name. 

Group Name 

Map the v3 user name into a group name. 

Security Level 

Select the security level of the v3 user to use. 

noauth

 means no authentication and no encryption. 

auth

 means messages are authenticated but not encrypted. 

priv

 means messages are authenticated and encrypted. 

Auth Algorithm 

Select 

MD5

 or 

SHA

 Algorithm when security level is 

auth

 or 

priv.

 

Auth Password 

Set the password for this user when security level is 

auth

 or 

priv. 

(pass phrases must be at least 8 characters long!) 

Priv Algorithm 

Select 

DES 

encryption when security level is 

priv.

 

Priv Password 

Set the password for this user when security level is 

priv. 

(pass 

phrases must be at least 8 characters long!) 

Apply 

Click 

Apply 

to configure the settings. 

Refresh 

Click 

Refresh 

to begin configuring this screen afresh. 

User Status 

Summary of Contents for NGI-S08C2POE8

Page 1: ......

Page 2: ...ce to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s ow...

Page 3: ...ld result in a hazardous situation to people and damage to the system Before performing any of the following procedures ensure that power is removed from the DC circuit Read the installation instructi...

Page 4: ...ts conductors or terminals Avoid using such interconnection methods unless the exposed metal parts are located within a restricted access location and users and service people who are authorized withi...

Page 5: ...4 3 1 2 WEB CONFIGURATION 29 4 3 2 PD ALIVE CHECK 30 4 3 2 1 CLI CONFIGURATION 31 4 3 2 2 WEB CONFIGURATION 32 4 3 3 POWER DELAY 33 4 3 3 1 CLI CONFIGURATION 33 4 3 3 2 WEB CONFIGURATION 34 4 3 4 POE...

Page 6: ...5 WEB CONFIGURATION 67 5 NETWORK TOPOLOGY 69 5 1 MAP SETTINGS 70 5 1 1 CLI CONFIGURATION 70 5 1 2 WEB CONFIGURATION 71 5 2 NEIGHBOR DEVICES 74 5 2 1 LLDP 74 5 2 1 1 CLI CONFIGURATION 74 5 2 1 2 WEB C...

Page 7: ...2 STORM CONTROL 112 6 5 2 1 CLI CONFIGURATION 112 6 5 2 2 WEB CONFIGURATION 113 6 6 VLAN 114 6 6 1 PORT ISOLATION 114 6 6 1 1 CLI CONFIGURATION 114 6 6 1 2 WEB CONFIGURATION 115 6 6 2 VLAN 116 6 6 2...

Page 8: ...8 2 SNMPV3 139 8 2 1 SNMPV3 GROUP 139 8 2 1 1 CLI CONFIGURATION 139 8 2 1 2 WEB CONFIGURATION 139 8 2 2 SNMPV3 USER 140 8 2 2 1 CLI CONFIGURATION 140 8 2 2 2 WEB CONFIGURATION 141 8 2 3 SNMPV3 VIEW 1...

Page 9: ...ol etc optimizes your network performance and provide a secure network offering a cost effective solution in a small but powerful package All Lite Managed switches are equipped with Tripp Lite s manag...

Page 10: ...LLDP ONVIF Topology Map Ethernet Interface 10 100 1000Base T interfaces Auto negotiation and Auto MDI MDI X Flow control of half duplex back pressure Flow control of full duplex Security 802 1X Radius...

Page 11: ...er size 4 1Mbit MAC Entries 8K Jumbo frame 10K Throughput 1 488 000pps when 1000Mbps speed Ports 10 100 1000Base T PSE 8 100FX Gigabit SFP slots 2 Power Input Voltage Primary input 24 57VDC at a maxim...

Page 12: ...10 to 60 14 F to 140 F Storage Temperature 40 to 75 40 F to 167 F Operating Humidity 10 to 95 RH non condensing Storage Humidity 5 to 95 RH non condensing Altitude Up to 2000 m 6561 ft IEC Indoor use...

Page 13: ...ces The following are recommended cabling for the RJ45 connectors 1 10Mbps Cat 3 or better 2 100 1000Mbps Cat 5e or better SFP Slots for SFP Modules The two SFP slots are designed to house 100FX Gigab...

Page 14: ...midity ranges Install the Switch in a location that is not affected by strong electromagnetic field generators such as motors vibration dust and direct sunlight Leave at least 10cm of space at the fro...

Page 15: ...st be permanently connected to earth ground to adequately ground the chassis and protect the operator from electrical hazards Attention The product should be mounted in an Industrial Control Panel and...

Page 16: ...maximum current allowable for each wire size If current exceeds the maximum rating the wiring can overheat causing serious damage to your equipment Please Read and Follow These Guidelines Use separate...

Page 17: ...wires The correct power supply voltage is listed on the product label Check the voltage of your power source to make sure that you are using the correct voltage Do NOT use a voltage greater than what...

Page 18: ...r on Off Redundant Power off or failure ALM Illuminated Alarm for following conditions when DIP switches are turned on Primary Power lost Secondary power lost If storm control exceeds the threshold If...

Page 19: ...r alarm reporting is disabled 2 RPS Redundant power input from terminal block ON Redundant power alarm reporting is enabled OFF Redundant power alarm reporting is disabled 3 STORM To enable disable st...

Page 20: ...on holes as heat dissipated passes through it ATTENTION This device complies with Part 15 of the FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interfer...

Page 21: ...nd subsequent steps after plug in 4 1 Wizard Settings Wizard will be use full to configure basic settings in the device like switch User account with device name management IP And access Mode The Wiza...

Page 22: ...22...

Page 23: ...23 Step 2 IPAddress is to configure the management IP user can select DHCP mode or static mode to configure the switch IP as shown below...

Page 24: ...Ps SSH and SNMPv3 and Normal mode HTTPs SSH SNMPv3 HTTP TELNET and SNMPv1 v2 Default Username admin Password admin After successful completion of the settings the web link will take you to the Topolog...

Page 25: ...Map The dashboard setting enables you to control the performance of the switch like CPU Memory Port Tx Usage Port Rx Usage Learn option to obtain to port registration information Parameter Descriptio...

Page 26: ...age User can configure threshold value to normal alert critical percentage or disable the feature Port Tx Usage User can configure threshold value to normal alert critical percentage of the interface...

Page 27: ...g Some are still in active use PSE Power sourcing equipment PSE is a device such as a switch that provides sources power on the Ethernet cable PD A powered device PD is a device such as an access poin...

Page 28: ...nges the node to configure node configure poe disable enable This command disables or enables the global PoE for the Switch configure poe total power This command configures the total power which the...

Page 29: ...al Power P Current of adaptor I Voltage of adaptor V Port Select a port or a range of ports which to configure loop detection State Selects Enable to enable the PoE function on the specific port Selec...

Page 30: ...2 PD Alive Check The function has a global state configuration If the global state configuration is enabled The Switch will check the configurations of every port If the port s state is enabled the Sw...

Page 31: ...the specific port interface pd alive action reboot alarm all none This command configures the action when the system detects that the host cannot respond the keep a live probe packet interface pd ali...

Page 32: ...f the host is still alive Retry Time The retry times when no response from the host for the keep a live probe packet Action The action to the Power Device when the system detects that the Power Device...

Page 33: ...his command enters the interface configure node interface poe power delay enable disable This command enables disables of the Power Delay function for the specific port interface poe power delay time...

Page 34: ...elects a port or a range of ports which you want to configure State Enables Disables the PoE Power Delay for the specific ports Time The delay time for the specific ports Apply Click Apply to take eff...

Page 35: ...rval between Start time and End Time the Switch will not send power to the port 4 3 4 1 CLI Configuration Node Command Description enable show poe schedule port PORT_ID This command displays the PoE p...

Page 36: ...ed Week Select a week day that you want to configure the schedule Check Enables or Disables the PoE schedule on the specific port for a defined time period Action Selects action enable disable for the...

Page 37: ...plex since they allow both callers to speak and be heard at the same time Loopback Test A loopback test is a test in which a signal in sent from a communications device and returned looped back to it...

Page 38: ...flow control in half duplex mode IEEE802 3x flow control is used in full duplex mode to send a pause signal to the sending port causing it to temporarily stop sending signals when the receiving port...

Page 39: ...range description STRINGs This command configures a description for the specific ports if range no description This command configures the default port description for the specific ports if range shut...

Page 40: ...configure flow control on interface on off Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Port Status Port This field displays the index nu...

Page 41: ...e loop detection is enabled the Switch will send one probe packets every two seconds and then wait for this packet If it receives the packet at the same port the Switch will disable this port After th...

Page 42: ...nd disables enables the loop detection on the port interface no shutdown This command enables the port It can unblock port blocked by loop detection interface loop detection recovery disable enable Th...

Page 43: ...port on which to configure loop guard protection State Select Enable to use the loop guard feature on that particular port of the Switch Recovery State Select Enable to reactivate the port automatical...

Page 44: ...us This field displays if the port is blocked Manual Recovery If the port is blocked by loop detection you can click Unblock to recovery it manually Recovery State This field displays if the loop reco...

Page 45: ...changes the node to configure node configure interface IFNAME This command enters the interface configure node interface default priority 0 7 This command allows the user to specify a default priority...

Page 46: ...nge of ports on which to configure the priority Priority Select a priority for packets received by the port Only packets without 802 1p priority tagged will be applied the priority you set here Apply...

Page 47: ...k that consists of conjoined Ethernet rings by one or more interconnection points The protection switching mechanisms and protocol defined in this Recommendation shall be applicable for a multi ring l...

Page 48: ...causing a switch has cleared the traffic channel is restored to the working transport entity i e blocked on the RPL In the case of clearing of a defect the traffic channel reverts after the expiry of...

Page 49: ...trol vlan 1 4094 This command configures a control vlan for the ERPS ring erps ring guard timer 10 2000 This command configures the Guard Timer for the ERPS ring default 500ms erps ring holdoff timer...

Page 50: ...e revertive mode Instance Configures the instance for the ring The Valid value is from 0 to 30 0 Disable means the ERPS is running in version 1 The control VLAN of the instance should be same as below...

Page 51: ...ect the settings Refresh Click Refresh to begin configuring this screen afresh ERPS Ring Status Ring ID The ring ID Ring Name The ring name State The ring state Revertive The ring revertive mode Contr...

Page 52: ...configures a new instance and specifies its control VLAN and data VLANs config erps inst no instance 1 2 This command removes an instance config erps inst show This command displays all of the instan...

Page 53: ...hout the network from the device that generates the topology change In STP a longer delay is required as the device that causes a topology change first notifies the root bridge and then the root bridg...

Page 54: ...through that port It is recommended to assign this value according to the speed of the bridge The slower the media the higher the cost How STP Works After a bridge determines the lowest cost spanning...

Page 55: ...ing state to prevent a loop Disabled Not strictly part of STP a network administrator can manually disable a port 802 1w RSTP In 1998 the IEEE with document 802 1w introduced an evolution of the Spann...

Page 56: ...Higher cost paths are more likely to be blocked by STP if a network loop is detected BPDU Guard This is a per port setting If the port is enabled in BPDU guard and receive any BPDU the port will be se...

Page 57: ...time configure no spanning tree algorithm timer This command configures the default values for forward time max age hello time configure spanning tree forward time 4 30 This command configures the br...

Page 58: ...time in seconds the Switch will wait before changing states This delay is required because every switch must receive information about topology changes before it starts to forward frames In addition...

Page 59: ...switch If all switches have the same priority the switch with the lowest MAC address will then become the root switch Enter a value from 0 61440 The lower the numeric value you assign the higher the p...

Page 60: ...value range 1 65535 32 bit based value range 1 200000000 interface no spanning tree cost This command configures the path cost to default for the specific port interface spanning tree port priority 0...

Page 61: ...rt priority to default for the specific port 4 5 2 2 2 eb Configuration Parameter Description STP Port Settings Port Selects a port that you want to configure Path Cost Configures the path cost for th...

Page 62: ...ole Should be one of the Alternated Designated Root Backup None Status The port s status Should be one of the Discarding Blocking Listening Learning Forwarding Disabled Path Cost The port s path cost...

Page 63: ...MODBUS TCP supports different types of data format for reading The primary four types of them are Data Access Type Function Code Function Name Note Bit access Physical Discrete Inputs 2 Read Discrete...

Page 64: ...nfigure the Switch to automatically learn multicast group membership of any VLANs The Switch then performs IGMP snooping on the first VLANs that send IGMP packets Alternatively you can specify the VLA...

Page 65: ...ode Command Description enable ping IPADDR c COUNT This command sends an echo request to the destination host The c parameter allow user to specific the packet count The default count is 4 enable ping...

Page 66: ...start The settings will take effect on next system restart Example The procedures to configure an IP address for the Switch To enter the configure node L2SWITCH configure terminal L2SWITCH config To e...

Page 67: ...odbus TCP State Select option to enable disable the Modbus TCP on the Switch IGMP Snooping Settings IGMP Snooping State Select Enable to activate IGMP Snooping to forward group multicast traffic only...

Page 68: ...o have the Switch re get an IP address from the DHCP server Select Disable if you want to configure the Switch s IP address manually IP Address Configures an IPv4 address for your Switch in dotted dec...

Page 69: ...ghbor device When move the mouse indicator on the Device icon it will display a few information about the connected device If the neighbor device is a Switch which supports Lamungan Management functio...

Page 70: ...isplays the Topology Map settings enable configure terminal This command changes the node to configure node configure topology map color HHHHHH This command configures the background color for the Top...

Page 71: ...ckground image so that you can identify easily where the switch has been placed Picture To choice a file which you want to display it in the background and the Preview window will display your selecti...

Page 72: ...ormat and its file size cannot be larger than 80 KB If you have download a picture before and then you want to download a new one The new one will update the old one Color Select the color for the bac...

Page 73: ...icture for the device ICON remapping The picture should be in GIF PNG JPG BMP format and its file size cannot be larger than 40 KB Preview To display your configurations and then make decision if appl...

Page 74: ...rmation to be accessed by a Network Management System NMS using a management protocol such as the Simple Network Management Protocol SNMP Default Settings The LLDP on the Switch is enabled Tx Interval...

Page 75: ...message TTL tx hold tx interval Time To Live The hold time for the Switch s information Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh LLDP...

Page 76: ...command changes the node to configure node configure manual registration device type ipcam plc switch pc mac MACADDR ip IPADDR product name STRINGS system name STRINGS This command configures a devic...

Page 77: ...ss of the device IP The IP address of the device Product Name The product name of the device System Name The system name of the device Apply Click Apply to take effect the settings Refresh Click Refre...

Page 78: ...to 10 ONVIF devices connected to it If one or more ONVIF devices are connected to the same port it displays the last ONVIF device gets connect to it 5 2 3 1 CLI Configuration Node Command Description...

Page 79: ...Switch Tx Interval Configures the sending ONVIF discovery packet interval Valid range is 6 3600 seconds Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this sc...

Page 80: ...N ID The VLAN ID of the ONVIF device join Product Name Name of the product added Product Type What kind of product that is added Model Model of the product Location Location where it is placed Web Ser...

Page 81: ...e neighbor device is a Switch which supports Lamungan server function click the right key of the mouse The menu will be displayed on the screen And then you can click an item which you want to configu...

Page 82: ...details of the devices connected to the host by placing the cursor on it When there is something wrong with the device the screen will appear as below so you can find the details of events that have g...

Page 83: ...wn below Non lite Switch menu Save All Device Location To fix the location of all devices on the map so that it restores its places after refresh Login Web GUI To log in to the client device web GUI a...

Page 84: ...84 5 3 2 Quick Configuration Menu By right clicking on the neighbor Lite management switch you get this menu you can configure as shown below...

Page 85: ...85 By right clicking on the neighbor switch only Lite management switches the following menu will appear and you can configure as shown below...

Page 86: ...ur Switch in dotted decimal notation For example 192 168 0 254 Subnet Mask Configures a IP subnet mask of your Switch in dotted decimal notation for example 255 255 255 0 Default Gateway Configures an...

Page 87: ...tection State Select option to enable disable the loop detection feature on port s Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Loop Dete...

Page 88: ...e port State Select option to enable disable the port Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Port Status Port This field displays t...

Page 89: ...ived and transmitted by this port will be copied to the destination port Destination Port Select a port which connects to a network traffic analyzer Apply Click Apply to take effect the settings Refre...

Page 90: ...5 3 2 6 Storm Control Configuration Parameter Description Storm Control Settings Port Select the port number for which you want to configure storm control settings Type Click the check box to enable...

Page 91: ...uration Click Save Configuration to save the current running configuration to the NVRAM 5 3 2 8 Save All Device Location To fix the location of all devices on the topology map so that it restores afte...

Page 92: ...ssword or digital certificate to the authenticator and the authenticator forwards the credentials to the authentication server for verification If the credentials are valid in the authentication serve...

Page 93: ...authentication Specify if a subscriber has to periodically re enter his or her user name and password to stay connected to the port Reauth period Specify how often a client has to re enter his or her...

Page 94: ...rver ip IP port PORTID This command configures the primary radius server configure dot1x radius primary server ip IP port PORTID key KEY This command configures the primary radius server configure dot...

Page 95: ...tocol used to authenticate users by means of an external server instead of an internal device user database that is limited to the memory capacity of the device In essence RADIUS allows you to validat...

Page 96: ...entication Method This field displays if the authentication method is Local or RADIUS Guest VLAN The field displays the guest vlan Primary Radius Server This field displays the IP address UDP port and...

Page 97: ...les disables the 802 1x on the port interface dot1x default This command sets the port configuration to default settings interface dot1x guest vlan disable enable This command configures the 802 1x st...

Page 98: ...g and outgoing packets on the port when a user has not passed 802 1x port authentication Select In to drop only incoming packets on the port when a user has not passed 802 1x port authentication Re au...

Page 99: ...2 1x port authentication settings back to default Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Port Status Port This field displays the p...

Page 100: ...ring results from the hit entries if more than one rule matches the actions and meter counters are taken from the policy associated with the matched rule with highest priority Default Settings Maximum...

Page 101: ...profile acl destination ip host IPADDR This command configures a specific destination IP address for the profile acl destination ip IPADDR IPMASK This command configures the destination IP address an...

Page 102: ...ig access list 111 L2SWITCH config acl vlan 2 L2SWITCH config acl source interface 1 L2SWITCH config acl show Profile Name 111 Activate disabled VLAN 2 Source Interface 1 Destination MAC Address any S...

Page 103: ...Configures the VLAN of the packets that you want to filter Source MAC Configures the source MAC of the packets that you want to filter Mask of Source MAC Configures the bitmap mask of the source MAC...

Page 104: ...urce IP field Destination IP Configures the destination IP of the packets that you want to filter Mask of Destination IP Configures the bitmap mask of the destination IP of the packets that you want t...

Page 105: ...s exceeded incoming packets with new MAC addresses are dropped It can be use MAC table to check it The static MAC addresses are included for the limit Note If you configure a port of the Switch from d...

Page 106: ...Security on the port Maximum MAC The maximum number of MAC addresses allowed per interface The acceptable range is 1 to 1000 Apply Click Apply to take effect the settings Refresh Click Refresh to beg...

Page 107: ...the HTTPS service on the Switch configure no https server This command disables the HTTPS service on the Switch configure http server restart This command restart the HTTP server If you have changed...

Page 108: ...v1 v2c service SNMPv3 Server State Selects Enable or Disable to enable or disable the SNMPv3 service SSH Server State Selects Enable or Disable to enable or disable the SSH service Telnet Server State...

Page 109: ...splays the current SNMPv1 v2c service status SNMPv3 Server Status Displays the current SNMPv3 service status SSH Server Status Displays the current SSH service status Telnet Server Status Displays the...

Page 110: ...he node to configure node configure bandwidth limit egress 0 62500 ports PORTLISTS This command enables the bandwidth limit for outgoing packets and set the limitation configure no bandwidth limit egr...

Page 111: ...configure the alarm threshold State Selects Enable Disable the alarm threshold for the port s Packet Type Selects packet type one of Broadcast Multicast Bcast Mcast Packet Rate Select the alarm thresh...

Page 112: ...broadcast multicast and unknown unicast packets in your network The default rate is 300pps for Broadcast and DLF You can set to maximum rate of 5000pps for multicast broadcast or DLF 6 5 2 1 CLI Conf...

Page 113: ...storm control Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Storm Control Status Port This field displays a port number Multicast Rate pps...

Page 114: ...rt 6 6 1 1 CLI Configuration Node Command Description enable show port isolation This command displays the current port isolation configurations V indicates the port s packets can be sent to that port...

Page 115: ...port means it will communicate with the port currently being configured Select All Deselect All Click Select All to mark all ports as egress ports and permit traffic Click Deselect All to unmark all p...

Page 116: ...o bytes of TCI Tag Control Information starts after the source address field of the Ethernet frame The CFI Canonical Format Indicator is a single bit flag always set to zero for Ethernet switches If a...

Page 117: ...segmentation If port to VLAN association is done with an application specific integrated circuit ASIC the performance is very good An ASIC allows the port to VLAN mapping to be done at the hardware l...

Page 118: ...he VLAN vlan fixed PORTLISTS This command assigns ports for permanent member of the VLAN vlan no fixed PORTLISTS This command removes all fixed member from the VLAN vlan tagged PORTLISTS This command...

Page 119: ...e drop down box Select All to configure all ports at the same time Role Select role on interface as access or trunk VLAN User can configure maximum of 5 VLAN s on each interface in the format 1 3 7 10...

Page 120: ...indicates if there is any alarm events Alarm Reason s This field displays all of the detail alarm events DIP switch Settings Storm The field displays the current Storm Control DIP settings Disable St...

Page 121: ...the current port mirroring configurations enable configure terminal This command changes the node to configure node configure mirror disable enable This command disables enables the port mirroring on...

Page 122: ...et the common settings and then make adjustments on a port by port basis Source Port Selects a port to monitor packets received and transmit or both Monitor Mode Select a port to monitor as destinatio...

Page 123: ...ormation Parameter Description Port Select a port or a range of ports to display their statistics Rx Packets The field displays the received packet count Tx Packets The field displays the transmitted...

Page 124: ...L2SWITCH show port utilization Kbps Port Speed Rx Utilization Rx Utilization Kbps Tx Utilization Tx Utilization Kbps 8 1000 0 00 8 0 00 0 L2SWITCH show port utilization Mbps Port Speed Rx Utilization...

Page 125: ...Command Description enable show syslog The command displays all of log message recorded in the Switch enable show syslog level 1 6 The command displays the log message with the level recorded in the...

Page 126: ...erver when any new log message occurred Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen afresh Log Level Select Alert Critical Error Warning Notice...

Page 127: ...y configure interface IFNAME This command enters the interface configure node interface port utilization threshold rate value This command configures the port utilization threshold value interface por...

Page 128: ...Rate Configures the threshold rate When the port packet rate over the threshold the Switch will send trap and syslog Apply Click Apply to take effect the settings Refresh Click Refresh to begin config...

Page 129: ...MP protocol globally By default SNMP state will be disabled User can change the system name with respect to their requirement also can add system location and contact location 8 1 1 1 CLI Configuratio...

Page 130: ...an SNMP v1 and SNMP v2c environments The default SNMP community is public for both SNMP v1 and SNMP v2c Network ID of Trusted Host The IP address is a combination of the Network ID and the Host ID Net...

Page 131: ...ges that are sent between the management station the SNMP manager and the device the SNMP agent The community string is included in every packet that is transmitted between the SNMP manager and the SN...

Page 132: ...nmp trap event alarm over heat disable enable This command enables disables the alarm over heat trap configure snmp trap event alarm over load disable enable This command enables disables the alarm ov...

Page 133: ...ture is too high Alarm Over Load Trap when system is over load Alarm Power Fail Trap when system power is over voltage under voltage RPS over voltage RPS under voltage BPDU Guard Trap when port is blo...

Page 134: ...134 Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring this screen afresh...

Page 135: ...ge trap This command enables the link change trap on the specific port interface no snmp port link change trap This command disables the link change trap on the specific port config interface range fa...

Page 136: ...136 Apply Click Apply to configure the settings Refresh Click Refresh to begin configuring this screen afresh...

Page 137: ...he remote trap station in dotted decimal notation Version Select the version of the Simple Network Management Protocol to use v1or v2c Community String Specify the community string used with this remo...

Page 138: ...138 Action Click Delete to remove a configured trap receiver station...

Page 139: ...p enable configure terminal This command changes the node to configure node configure snmp group GROUPNAME noauth read STRINGS write STRINGS notify STRINGS Configurs v3 group of non authentication con...

Page 140: ...l This field displays the security model of the group Always displayed v3 User based Security Model USM Security Level This field displays the security level to this group Read View These fields displ...

Page 141: ...authenticated and encrypted Auth Algorithm Select MD5 or SHA Algorithm when security level is auth or priv Auth Password Set the password for this user when security level is auth or priv pass phrase...

Page 142: ...ode Command Description enable show snmp view This command displays all snmp v3 view enable configure terminal This command changes the node to configure node configure snmp view VIEWNAME STRINGS incl...

Page 143: ...ew name View Subtree This field displays the subtree View Type This field displays the subtree adding to the view or not Action Click Delete to remove a v3 view 8 3 SNTP The Network Time Protocol NTP...

Page 144: ...ault SNTP server 8 3 1 CLI Configuration Node Command Description enable show time This command displays current time and time configurations enable configure terminal This command changes the node to...

Page 145: ...P address of your time server configure time timezone STRING Configures the time difference between UTC formerly known as GMT and your time zone Valid value 1200 1200 8 3 2 Web Configuration Parameter...

Page 146: ...Saving Time starts in most parts of the United States on the second Sunday of March Each time zone in the United States starts using Daylight Saving Time at 2 A M local time So in the United States y...

Page 147: ...C So in the European Union you would select Last Sunday 10 October and the last field depends on your time zone In Germany for instance you would select 2 00 because Germany s time zone is one hour ah...

Page 148: ...n of switch like vendor product mac address serial boot code firmware version etc enable show system info This command will display information of CPU loading and memory usage etc enable show uptime T...

Page 149: ...command changes the node to configure node configure write memory This command writes current operating configurations to the configuration file configure archive download config URL PATH This command...

Page 150: ...ing configurations to startup config file When the Switch boot up it will load startup config as the system configurations When users execute the command reload default config the system will copy use...

Page 151: ...ation file which you want to upgrade it to the Switch Click the Upload button to start the upgrade procedures Click the Download button to download the current configurations to local host Reset Confi...

Page 152: ...download fw URL PATH This command downloads a new copy of firmware file from TFTP FTP HTTP server Where URL PATH can be ftp user pass 192 168 1 1 file http 192 168 1 1 file tftp 192 168 1 1 file 8 5...

Page 153: ...nfiguration Node Command Description enable configure terminal This command changes the node to configure node configure reboot This command reboots the system 8 5 3 2 Web Configuration Click the Rebo...

Page 154: ...to enter the Switch and then create a new user account Notices The Switch allows users to create up to 6 dot1x user account and 6 non dot1x user account The user name and the password should be the co...

Page 155: ...associates admin read and write or normal read only or dot1x Dot1X user for local authentication Apply Click Apply to take effect the settings Refresh Click Refresh to begin configuring this screen a...

Page 156: ...otherwise PRODUCT REGISTRATION Visit www tripplite com warranty today to register your new Tripp Lite product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite prod...

Page 157: ...ved by Tripp Lite could void the user s authority to operate this equipment Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos and illustratio...

Reviews: