www.trilithic.com
Page VI-6
720 DSP Operation Manual
Business Services Meter
Carrier-to-Noise Measurement
In-service, non-scrambled standard channels only
Minimum Input
Level for Full
Range
+10 dBmV
Dynamic Range
50 dB
Resolution
< 0.5 dB
Tilt Measurement
Max Number of
Carriers
14 (dependent on favorite channel setup)
High/Low Delta
Resolution
0.1 dB
Scan
Video, audio, pilot, and digital carriers
HUM Measurement
In-service, non-scrambled standard channels only
Minimum Input
Level
0 dBmV
Range
0% to 5%
Resolution
0.1%
Accuracy
±0.5%