![Trilithic 720 DSP Operation Manual Download Page 349](http://html.mh-extra.com/html/trilithic/720-dsp/720-dsp_operation-manual_1162680349.webp)
www.trilithic.com
Page IV-129
720 DSP Operation Manual
Business Services Meter
Ping Mode
When the
Ping
mode is selected, the
following measurement results are
displayed as shown in the image to the
right:
• Minimum Time
– This is the
minimum time required to send/
receive a single test packet.
• Average Time
– This is the
average time required to send/
receive all test packets.
• Maximum Time
– This is the maximum time required to send/receive a single test
packet.
• Sent
– This is the number of packets sent by the 720 DSP to the destination IP
address.
• Received
– This is the number of packets received by the 720 DSP from the
destination IP address.
• LPR
– This is the lost packet ratio. This measurement is displayed in the bar graph
and as a numeric value. The LPR is calculated as the percentage of packets
received to those which were sent (LPR = {Received Packets / Sent Packets} *
100%), for example:
• 50 sent packets
• 25 received packets
• LPR = {25 / 50} * 100%
{0.50} * 100%
50%
Summary of Contents for 720 DSP
Page 23: ...www trilithic com 720 DSP Business Certification Meter Section I The Basics ...
Page 79: ...www trilithic com 720 DSP Business Certification Meter Section II Setup Menu ...
Page 199: ...www trilithic com 720 DSP Business Certification Meter Section III Autotest Menu ...
Page 221: ...www trilithic com 720 DSP Business Certification Meter Section IV Troubleshoot Menu ...
Page 413: ...www trilithic com 720 DSP Business Certification Meter Section V Utility Menu ...
Page 429: ...www trilithic com 720 DSP Business Certification Meter Section VI Appendix ...
Page 440: ...9710 Park Davis Drive Indianapolis IN 46235 317 895 3600 www trilithic com Made in U S A ...