720 DSP Operation Manual
Business Services Meter
Optimal Modulation
The
Optimal Modulation
setting is used
to set the marker on the % modulation bar
graph to compute signal level for analog
channels with SECAM L modulation.
The default setting for the optimal
modulation is
87.5%
. The optimal
modulation can be set from a minimum of
70.0% up to a maximum of 99.0%.
Use either of the following methods to
change the optimal modulation:
• Use the up/down arrow buttons
to change the value in 0.1%
increments.
• Press the
Enter
button and use the
Virtual Keyboard
to directly enter
the optimal modulation as shown in
the image to the right.