HUM
The HUM feature provides users with the ability to measure the amplitude of the 50/60
Hz, 100/120 Hz, and low frequency interference present on the video carrier of a single
carrier channel.
Select the
Hum
button from the
Display
pop-up menu to display a bar
graph of the HUM levels of the analog
channel.
The following measurement results
are displayed with a pass/fail status for
each measurement that is included in
the open limit set:
• 60 Hz level value with bar graph
• 120 Hz level value with bar graph
• < 1 kHz (low frequency) level value