www.trilithic.com
Page IV-99
720 DSP Operation Manual
Business Services Meter
Start Frequency Adjustment
Highlight the
Mode: Start/Stop
field as
shown in the image to the right. Use the
up/down arrow buttons to set it to
Start/
Stop.
Highlight the
Start
frequency field as
shown in the image below (left) and then
use either of the following methods to
change the start frequency:
• Use the up/down arrow buttons to
adjust the frequency in 0.1 MHz
increments.
• Press the
Enter
button and use
the
Virtual Keyboard
to directly enter the start
frequency as shown in the image below (right).
Vertical Scale Adjustment
Highlight the vertical scale field as shown
in the image to the right. Then, use the
up/down arrow buttons to select from a
vertical scale of
1
,
2
,
5
or
10
dB/div
.
Summary of Contents for 720 DSP
Page 23: ...www trilithic com 720 DSP Business Certification Meter Section I The Basics ...
Page 79: ...www trilithic com 720 DSP Business Certification Meter Section II Setup Menu ...
Page 199: ...www trilithic com 720 DSP Business Certification Meter Section III Autotest Menu ...
Page 221: ...www trilithic com 720 DSP Business Certification Meter Section IV Troubleshoot Menu ...
Page 413: ...www trilithic com 720 DSP Business Certification Meter Section V Utility Menu ...
Page 429: ...www trilithic com 720 DSP Business Certification Meter Section VI Appendix ...
Page 440: ...9710 Park Davis Drive Indianapolis IN 46235 317 895 3600 www trilithic com Made in U S A ...