Velocity of Propagation
The
Velocity of Propagation
setting is
used to set the propagation value for the
cable under test.
The default setting for the velocity of
propagation is
82.0%
. The velocity of
propagation can be set from a minimum of
60.0% up to a maximum of 99.0%.
Use either of the following methods to
change the velocity of propagation:
• Use the up/down arrow buttons
to change the value in 0.1%
increments.
• Press the
Enter
button and use
the
Virtual Keyboard
to directly
enter the velocity of propagation as
shown in the image to the right.
Hum Type
The
Hum Type
setting is used to set the
default hum type for testing.
The default setting for
Hum Type
is
60
Hz
, use the up/down arrow buttons to
select from the following preset values:
• 60 Hz
• 50 Hz
Summary of Contents for 720 DSP
Page 23: ...www trilithic com 720 DSP Business Certification Meter Section I The Basics ...
Page 79: ...www trilithic com 720 DSP Business Certification Meter Section II Setup Menu ...
Page 199: ...www trilithic com 720 DSP Business Certification Meter Section III Autotest Menu ...
Page 221: ...www trilithic com 720 DSP Business Certification Meter Section IV Troubleshoot Menu ...
Page 413: ...www trilithic com 720 DSP Business Certification Meter Section V Utility Menu ...
Page 429: ...www trilithic com 720 DSP Business Certification Meter Section VI Appendix ...
Page 440: ...9710 Park Davis Drive Indianapolis IN 46235 317 895 3600 www trilithic com Made in U S A ...