![Trilithic 720 DSP Operation Manual Download Page 411](http://html.mh-extra.com/html/trilithic/720-dsp/720-dsp_operation-manual_1162680411.webp)
www.trilithic.com
Page IV-191
720 DSP Operation Manual
Business Services Meter
Once you have your levels at the
node set up correctly, you can store
a reference and use that reference
at the next amplifier to adjust for
gain and tilt. The image on the right
shows the previous graph but with a
reference stored.
The Zoom button is currently still under development.
Once you have stored a reference,
you can go to the next amp in line
and compare the referenced display
from the node (image above) to the
local display at the amp (image to
the right), which will allow you to
EQ and/or pad to get the upstream
aligned.